Nocturnal ultrafiltration profiles in patients on APD: impact on fluid and solute transport.

N D Vega1, R Gallego, E Oliva, F Henriquez, L Palop, J C Divino Filho, B Lindholm.   

Abstract

In order to prevent morbidity and mortality in peritoneal dialysis (PD), sodium and water balance as well as a minimal level of small-solute clearances are needed. The impact of three nocturnal peritoneal ultrafiltration (UF) profiles on UF and small solute clearance in patients on automated PD (APD) was studied: constant glucose concentration of 1.36% (flat) or modifying the glucose concentration of the heater bag (descendant: 3.86-1.36%; ascendant: 1.36-3.86%). Sixty-two patients were enrolled in the study and received each profile within a four-month period, thus serving as their own controls. UF was lower with the flat profile (367+/-420ml; P<0.01), but no difference was seen between the two higher glucose concentration profiles. Peritoneal Kt/V (pKt/V) and peritoneal creatinine clearance (CrpC) showed statistically higher values from the descendant vs ascendant vs flat profiles (pKt/V: 1.54+/-0.30 vs 1.45+/-0.30 vs 1.38+/-0.27, and CrpC: 36.9+/-7.9 vs 33.5+/-7.48 vs 29.92+/-7.5 mlmin(-1)). Multivariate analysis showed statistical significance for the following: in the intrasubject comparisons, the profile for pKt/V (F=9.109, P<0.001) and CrpC (F=11.697, P<0.001), and in the intersubjects comparisons, the effects of both gender (F=14.334, P<0.01) for pKt/V and peritoneal permeability for both parameters (pKt/V: F=4.37, P<0.05; CrpC: F=11.697, P<0.001). In conclusion, the application of ascendant and descendant UF profiles in automated PD is feasible and results in better UF and small solute clearances, thus preventing inadequate dialysis and volume overload..

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18379556     DOI: 10.1038/sj.ki.5002609

Source DB:  PubMed          Journal:  Kidney Int Suppl        ISSN: 0098-6577            Impact factor:   10.545


  2 in total

1.  Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.

Authors:  Xue-Ying Cao; Ya-Ni He; Jian-Hui Zhou; Shi-Ren Sun; Li-Ning Miao; Wen Chen; Jing-Ai Fang; Ming Wang; Nian-Song Wang; Hong-Li Lin; Jian Liu; Zhao-Hui Ni; Wen-Hu Liu; Yu Na; Jiu-Yang Zhao; Zhi-Yong Guo; Hong-Guang Zheng; Wei Shi; Geng-Ru Jiang; Guang-Yan Cai; Xiang-Mei Chen
Journal:  Chin Med J (Engl)       Date:  2018-12-05       Impact factor: 2.628

2.  Renal Replacement Therapy: Purifying Efficiency of Automated Peritoneal Dialysis in Diabetic versus Non-Diabetic Patients.

Authors:  Nicanor Vega-Diaz; Fayna Gonzalez-Cabrera; Silvia Marrero-Robayna; Raquel Santana-Estupiñan; Roberto Gallego-Samper; Fernando Henriquez-Palop; Patricia Perez-Borges; José Carlos Rodriguez-Perez
Journal:  J Clin Med       Date:  2015-07-22       Impact factor: 4.241