Literature DB >> 18379534

Effects of peritoneal dialysis fluid biocompatibility on baroreflex sensitivity.

S G John1, N M Selby, C W McIntyre.   

Abstract

Conventional low biocompatibility peritoneal dialysis (PD) fluid composition has been driven by manufacturing expediency and cost limitations. PD is associated with significant acute changes in cardiovascular functional parameters, at least in part influenced by fluid composition. Short-term control of blood pressure (BP) is under control of the baroreflex arc. The aim of this study was to investigate the effects of PD fluid biocompatibility on baroreflex sensitivity (BRS). We studied 10 non-diabetic established continuous ambulatory PD patients, in a randomized crossover trial comparing conventional and biocompatible PD fluids. Systemic hemodynamics were continuously monitored using digital pulse-wave analysis. Plasma glucose and insulin were assessed during treatment with both 1.36% and 3.86% glucose-containing fluids. BRS was calculated offline from continuous BP and interbeat interval data. BRS was significantly higher with conventional PD fluid during both 1.36% (P<0.001) and 3.86% (P<0.001) dwells. Systolic BP was higher; heart rate, stroke volume, and cardiac output were lower; and total peripheral resistance increased during exposure to either fluid. There were significant differences between fluids with respect to the magnitude of these responses. Plasma glucose and insulin concentrations, and ultrafiltration volumes were significantly higher during the 3.86% dwell than the 1.36% dwell, but there were no differences between standard and biocompatible fluids. We have demonstrated for the first time that PD fluid biocompatibility rapidly affects BRS. These changes occur against a background of cardiovascular variability, hyperinsulinemia, and hyperglycemia. Further research is needed to explore the mechanism and, more importantly, the consequences of these findings.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18379534     DOI: 10.1038/sj.ki.5002612

Source DB:  PubMed          Journal:  Kidney Int Suppl        ISSN: 0098-6577            Impact factor:   10.545


  6 in total

1.  Effect of icodextrin on heart rate variability in diabetic patients on peritoneal dialysis.

Authors:  Oscar Orihuela; María de Jesús Ventura; Marcela Ávila-Díaz; Alejandra Cisneros; Marlén Vicenté-Martínez; María-del-Carmen Furlong; Zuzel García-González; Diana Villanueva; Guadalupe Alcántara; Bengt Lindholm; Elvia García-López; Cleva Villanueva; Ramón Paniagua
Journal:  Perit Dial Int       Date:  2014 Jan-Feb       Impact factor: 1.756

2.  Association of impaired baroreflex sensitivity and increased arterial stiffness in peritoneal dialysis patients.

Authors:  Amit Gupta; Gaurav Jain; Manpreet Kaur; Ashok Kumar Jaryal; Kishore Kumar Deepak; Dipankar Bhowmik; Sanjay Kumar Agarwal
Journal:  Clin Exp Nephrol       Date:  2015-09-05       Impact factor: 2.801

3.  Biphasic Regulation of Lipid Metabolism: A Meta-Analysis of Icodextrin in Peritoneal Dialysis.

Authors:  Yan-Feng Huang; Da-Jian Zhu; Xiao-Wu Chen; Man-Zhao Ouyang; Wei-Jie Zhang
Journal:  Biomed Res Int       Date:  2015-12-15       Impact factor: 3.411

4.  Advances in the cardiovascular assessment of patients with chronic kidney disease.

Authors:  Chris W McIntyre; Stephen G John; Helen J Jefferies
Journal:  NDT Plus       Date:  2008-09-08

5.  Biocompatible peritoneal dialysis fluids: clinical outcomes.

Authors:  Yeoungjee Cho; Sunil V Badve; Carmel M Hawley; Kathryn Wiggins; David W Johnson
Journal:  Int J Nephrol       Date:  2012-11-28

6.  Biocompatible dialysis fluids for peritoneal dialysis.

Authors:  Htay Htay; David W Johnson; Kathryn J Wiggins; Sunil V Badve; Jonathan C Craig; Giovanni Fm Strippoli; Yeoungjee Cho
Journal:  Cochrane Database Syst Rev       Date:  2018-10-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.