Literature DB >> 18379324

Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging.

Kaori Furutani1, Masafumi Harada, Mahmut Mawlan, Hiromu Nishitani.   

Abstract

OBJECTIVE: To compare the enhancement of brain metastasis between 3-dimensional fast spoiled gradient recalled acquisition in the steady state (3DFSPGR) and spin echo (SE) T1-weighted imaging at 3-T magnetic resonance imaging.
METHODS: The subjects comprised 18 patients with 81 suspected brain metastases. Axial SE and 3DFSPGR images were obtained before and after gadoteridol injection. The signal intensity of each tumor was measured for each sequence; the enhancement and contrast rates were also calculated.
RESULTS: For equivalent slice thicknesses, the enhancement and contrast rates of the 3DFSPGR images were lower than those of the SE images (<0.05), whereas for the thin slices, the rates were higher for the 3DFSPGR images (P < 0.01).
CONCLUSIONS: On 3-T magnetic resonance imaging, the enhancement of 3DFSPGR images was less than that of the SE images under the same conditions, but not to a fatal degree, and thin slice 3DFSPGR imaging is therefore considered to be useful for detecting small lesions, when given a high dose of contrast agent and a suitable scanning delay time.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18379324     DOI: 10.1097/RCT.0b013e318074fd9d

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  24 in total

1.  MR diagnosis of facial neuritis: diagnostic performance of contrast-enhanced 3D-FLAIR technique compared with contrast-enhanced 3D-T1-fast-field echo with fat suppression.

Authors:  H K Lim; J H Lee; D Hyun; J W Park; J L Kim; H y Lee; S Park; J H Ahn; J H Baek; C G Choi
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-29       Impact factor: 3.825

2.  Additional MR contrast dosage for radiologists' diagnostic performance in detecting brain metastases: a systematic observer study at 3 T.

Authors:  Osamu Togao; Akio Hiwatashi; Koji Yamashita; Kazufumi Kikuchi; Takashi Yoshiura; Hiroshi Honda
Journal:  Jpn J Radiol       Date:  2014-06-24       Impact factor: 2.374

Review 3.  The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seung Chai Jung; Kyung Won Kim; Junhee Pyo
Journal:  J Neurooncol       Date:  2016-06-20       Impact factor: 4.130

Review 4.  Brain miliary enhancement.

Authors:  Joseph C J Bot; Linda Mazzai; Rogier E Hagenbeek; Silvia Ingala; Bob van Oosten; Esther Sanchez-Aliaga; Frederik Barkhof
Journal:  Neuroradiology       Date:  2020-01-10       Impact factor: 2.804

5.  Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases.

Authors:  Timothy J Kaufmann; Marion Smits; Jerrold Boxerman; Raymond Huang; Daniel P Barboriak; Michael Weller; Caroline Chung; Christina Tsien; Paul D Brown; Lalitha Shankar; Evanthia Galanis; Elizabeth Gerstner; Martin J van den Bent; Terry C Burns; Ian F Parney; Gavin Dunn; Priscilla K Brastianos; Nancy U Lin; Patrick Y Wen; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2020-06-09       Impact factor: 12.300

6.  Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

Authors:  Richard Keith Downs; Mariah Haider Bashir; Chin Kau Ng; Jens Olaf Heidenreich
Journal:  Quant Imaging Med Surg       Date:  2013-06

7.  Inverse spatial distribution of brain metastases and white matter hyperintensities in advanced lung and non-lung cancer patients.

Authors:  Carlo Cosimo Quattrocchi; Yuri Errante; Carlo Augusto Mallio; Luciano Carideo; Laura Scarciolla; Daniele Santini; Giuseppe Tonini; Bruno Beomonte Zobel
Journal:  J Neurooncol       Date:  2014-07-22       Impact factor: 4.130

8.  3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3T MR imaging.

Authors:  E Nagao; T Yoshiura; A Hiwatashi; M Obara; K Yamashita; H Kamano; Y Takayama; K Kobayashi; H Honda
Journal:  AJNR Am J Neuroradiol       Date:  2011-02-03       Impact factor: 3.825

9.  Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

Authors:  Balaji Jeevanandham; Tejas Kalyanpur; Prashant Gupta; Mathew Cherian
Journal:  Br J Radiol       Date:  2017-04-26       Impact factor: 3.039

10.  Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging.

Authors:  Y Kato; S Higano; H Tamura; S Mugikura; A Umetsu; T Murata; S Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.