Literature DB >> 18375134

Radionuclide calibrator measurements of (18)F in a 3ml plastic syringe.

J T Cessna1, M K Schultz, T Leslie, N Bores.   

Abstract

This paper discusses the calibration of Capintec radionuclide calibrators for the measurement of (18)F in the pharmacy and clinic. In support of a planned regional comparison, a secondary laboratory was set up at Oak Ridge National Laboratories in Oak Ridge, TN. The laboratory was used to prepare 1mL (18)F-fluorodeoxyglucose sources in 3mL plastic BD syringes (Becton, Dickinson and Company, Franklin Lakes, New Jersey, USA) and to determine dial settings in three models of radionuclide calibrators. Measurements were verified by comparing radionuclide calibrator measurements of a 5mL ampoule source with previous results. The CIEMAT/NIST method of tritium efficiency tracing was used for activity determinations.

Entities:  

Year:  2008        PMID: 18375134     DOI: 10.1016/j.apradiso.2008.02.046

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  7 in total

1.  Standardization of I-124 by three liquid scintillation-based methods.

Authors:  D E Bergeron; J T Cessna; R Fitzgerald; L Pibida; B E Zimmerman
Journal:  Appl Radiat Isot       Date:  2019-08-09       Impact factor: 1.513

2.  Precise activity measurements of medical radionuclides using an ionization chamber: a case study with Terbium-161.

Authors:  Frédéric Juget; Zeynep Talip; Youcef Nedjadi; M Teresa Durán; Pascal V Grundler; Jan Rijn Zeevaart; Nicholas P van der Meulen; Claude Bailat
Journal:  EJNMMI Phys       Date:  2022-03-14

3.  Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography.

Authors:  H Umesha Shetty; Cheryl L Morse; Victor W Pike
Journal:  ACS Meas Sci Au       Date:  2022-06-23

4.  Characterization of fast-decaying PET radiotracers solely through LC-MS/MS of constituent radioactive and carrier isotopologues.

Authors:  H Umesha Shetty; Cheryl L Morse; Yi Zhang; Victor W Pike
Journal:  EJNMMI Res       Date:  2013-01-12       Impact factor: 3.138

5.  A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Bert M Coursey; Ryan Fitzgerald; Brian E Zimmerman
Journal:  J Res Natl Inst Stand Technol       Date:  2014-08-27

6.  A recommendation for revised dose calibrator measurement procedures for 89Zr and 124I.

Authors:  Bradley J Beattie; Keith S Pentlow; Joseph O'Donoghue; John L Humm
Journal:  PLoS One       Date:  2014-09-09       Impact factor: 3.240

7.  Development of a non-radiometric method for measuring the arterial input function of a 11C-labeled PET radiotracer.

Authors:  H Umesha Shetty; Sami S Zoghbi; Cheryl L Morse; Aneta Kowalski; Jussi Hirvonen; Robert B Innis; Victor W Pike
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.996

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.