Literature DB >> 18372416

Subtraction 3D CT angiography with the orbital synchronized helical scan technique for the evaluation of postoperative cerebral aneurysms treated with cobalt-alloy clips.

Y Watanabe1, N Kashiwagi, N Yamada, M Higashi, T Fukuda, S Morikawa, Y Onishi, K Iihara, S Miyamoto, H Naito.   

Abstract

BACKGROUND AND
PURPOSE: CT angiography (CTA) has been used for the evaluation of intracranial aneurysms and recently has been applied to assess postoperative aneurysms treated with titanium-alloy clips. We investigated the clinical usefulness of subtraction CTA by using the orbital synchronized helical scan technique (OSHST) for evaluating intracranial aneurysms surgically treated with cobalt-alloy clips.
MATERIALS AND METHODS: We scanned an agar gel phantom with a cobalt-alloy clip mounted in the center by using subtraction CT with and without OSHST. Eighteen patients (20 aneurysms) who underwent surgery with cobalt-alloy clips were postoperatively evaluated with subtraction CTA with OSHST, and the results were compared with those from digital subtraction angiography. Two neuroradiologists independently evaluated the 3D CTA images and source images with and without subtraction for the presence of residual flow in the aneurysm and stenotic change in parent or neighboring arteries.
RESULTS: For the phantom study, significantly fewer artifacts from clips were noted on images obtained by using subtraction CT with OSHST than on those obtained without OSHST. For the clinical study, subtraction CTA with OSHST also showed fewer clip artifacts than did conventional CTA. Image quality was poor, and we were unable to diagnose residual neck for 5% (1/20) with subtraction CTA with OSHST and 75% (15/20) with conventional CTA. For evaluation of adjacent vessels, image quality was poor for none (0/20) with subtraction CTA with OSHST and for 55% (11/20) with conventional CTA. For subtraction CTA with OSHST, sensitivity in detecting residual neck was 1.0, and specificity was 0.94. For conventional CTA, sensitivity and specificity were both 0.25.
CONCLUSIONS: OSHST is a useful technique for subtracting cobalt-alloy clips, and subtraction CTA with OSHST is available for evaluating aneurysms after clipping with cobalt-alloy clips.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18372416      PMCID: PMC8118823          DOI: 10.3174/ajnr.A1040

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study.

Authors:  H W Venema; F J Hulsmans; G J den Heeten
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

Review 2.  What percentage of surgically clipped intracranial aneurysms have residual necks?

Authors:  J Thornton; Q Bashir; V A Aletich; G M Debrun; J I Ausman; F T Charbel
Journal:  Neurosurgery       Date:  2000-06       Impact factor: 4.654

3.  Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience--rediscovery of matched mask bone elimination?

Authors:  Hank W Venema; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2003-08       Impact factor: 3.825

4.  Minimizing clip artifacts in multi CT angiography of clipped patients.

Authors:  I van der Schaaf; M van Leeuwen; A Vlassenbroek; B Velthuis
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

5.  Bone-subtraction CT angiography for the evaluation of intracranial aneurysms.

Authors:  B F Tomandl; T Hammen; E Klotz; H Ditt; B Stemper; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

6.  Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography.

Authors:  S Sakamoto; Y Kiura; M Shibukawa; S Ohba; K Arita; K Kurisu
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

7.  Comparison of multislice computerized tomography angiography and digital subtraction angiography in the postoperative evaluation of patients with clipped aneurysms.

Authors:  Amir R Dehdashti; Stefano Binaghi; Antoine Uske; Luca Regli
Journal:  J Neurosurg       Date:  2006-03       Impact factor: 5.115

8.  Limitations of three-dimensional reconstructed computerized tomography angiography after clip placement for intracranial aneurysms.

Authors:  Yoshiko Sagara; Hiro Kiyosue; Yuzo Hori; Michifumi Sainoo; Hirofumi Nagatomi; Hiromu Mori
Journal:  J Neurosurg       Date:  2005-10       Impact factor: 5.115

9.  Risk of aneurysm recurrence in patients with clipped cerebral aneurysms: results of long-term follow-up angiography.

Authors:  K Tsutsumi; K Ueki; A Morita; M Usui; T Kirino
Journal:  Stroke       Date:  2001-05       Impact factor: 7.914

10.  Yield of screening for new aneurysms after treatment for subarachnoid hemorrhage.

Authors:  M J H Wermer; E Buskens; I C van der Schaaf; P M M Bossuyt; G J E Rinkel
Journal:  Neurology       Date:  2004-02-10       Impact factor: 9.910

View more
  12 in total

1.  Subtraction CT angiography for the diagnosis of iliac arterial steno-occlusive disease.

Authors:  Michiko Suzuki; Ryoichi Tanaka; Kunihiro Yoshioka; Akihiko Abiko; Shigeru Ehara
Journal:  Jpn J Radiol       Date:  2015-12-18       Impact factor: 2.374

2.  Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction.

Authors:  Ryoichi Tanaka; Kunihiro Yoshioka; Kenta Muranaka; Takuya Chiba; Takanori Ueda; Tadashi Sasaki; Tetsuya Fusazaki; Shigeru Ehara
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-25       Impact factor: 2.357

3.  Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Hideaki Yuki; Kenichiro Hirarta; Seitaro Oda; Masafumi Kidoh; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2017-01-03       Impact factor: 2.804

4.  256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference.

Authors:  Hye Jeong Kim; Dae Young Yoon; Eun Soo Kim; Eun Joo Yun; Hong Jun Jeon; Jong Young Lee; Byung-Moon Cho
Journal:  Eur Radiol       Date:  2019-12-16       Impact factor: 5.315

5.  Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms.

Authors:  M-N Psychogios; D Wachter; A Mohr; P Schramm; A-M Frölich; K Jung; V Rohde; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

6.  Quantitative analysis of factors affecting cobalt alloy clip artifacts in computed tomography.

Authors:  Sook Young Sim; Chi Hoon Choi
Journal:  J Korean Neurosurg Soc       Date:  2014-11-30

7.  Reduction of misregistration on cerebral four-dimensional computed tomography angiography images using advanced patient motion correction reconstruction.

Authors:  Yuki Kunitomi; Yoshiyuki Watanabe; Atsuko Arisawa; Akio Tsukabe; Hisashi Tanaka; Hiroto Takahashi; Takeo Nishida; Manabu Kinoshita; Hajime Nakamura; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2016-07-05       Impact factor: 2.374

Review 8.  Aneurysmal subarachnoid haemorrhage from a neuroimaging perspective.

Authors:  Airton Leonardo de Oliveira Manoel; Ann Mansur; Amanda Murphy; David Turkel-Parrella; Matt Macdonald; R Loch Macdonald; Walter Montanera; Thomas R Marotta; Aditya Bharatha; Khaled Effendi; Tom A Schweizer
Journal:  Crit Care       Date:  2014-11-13       Impact factor: 9.097

9.  3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms--assessment of feasibility and image quality.

Authors:  Thomas Westermaier; Thomas Linsenmann; György A Homola; Mario Loehr; Christian Stetter; Nadine Willner; Ralf-Ingo Ernestus; Laszlo Solymosi; Giles H Vince
Journal:  BMC Med Imaging       Date:  2016-04-19       Impact factor: 1.930

10.  Ultra-high-resolution subtraction CT angiography in the follow-up of treated intracranial aneurysms.

Authors:  Frederick J A Meijer; Joanne D Schuijf; Joost de Vries; Hieronymus D Boogaarts; Willem-Jan van der Woude; Mathias Prokop
Journal:  Insights Imaging       Date:  2019-01-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.