Literature DB >> 18371840

Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions.

Ivana Cesarino1, Glimaldo Marino, Jivaldo do Rosário Matos, Eder Tadeu Gomes Cavalheiro.   

Abstract

The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the simultaneous determination of Pb(II), Cu(II) and Hg(II) ions in natural water and sugar cane spirit (cachaça) is described. Pb(II), Cu(II) and Hg(II) were pre-concentrated on the surface of the modified electrode by complexing with 2-benzothiazolethiol and reduced at a negative potential (-0.80 V). Then the reduced products were oxidised by DPASV procedure. The fact that three stripping peaks appeared on the voltammograms at the potentials of -0.48 V (Pb2+), -0.03 V (Cu2+) and +0.36 V (Hg2+) in relation to the SCE, demonstrates the possibility of simultaneous determination of Pb2+, Cu2+ and Hg2+. The best results were obtained under the following optimised conditions: 100 mV pulse amplitude, 3 min accumulation time, 25 mV s(-1) scan rate in phosphate solution pH 3.0. Using such parameters, calibration graphs were linear in the concentration ranges of 3.00-70.0 x 10(-7) mol L(-1) (Pb2+), 8.00-100.0 x 10(-7) mol L(-1) (Cu2+) and 2.00-10.0 x 10(-6) mol L(-1) (Hg2+). Detection limits of 4.0 x 10(-8) mol L(-1) (Pb2+), 2.0 x 10(-7) mol L(-1) (Cu2+) and 4.0 x 10(-7) mol L(-1) (Hg2+) were obtained at the signal noise ratio (SNR) of 3. The results indicate that this electrode is sensitive and effective for simultaneous determination of Pb2+, Cu2+ and Hg2+ in the analysed samples.

Entities:  

Year:  2007        PMID: 18371840     DOI: 10.1016/j.talanta.2007.06.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Palygorskite modified with N-doped carbon for sensitive determination of lead(II) by differential pulse anodic stripping voltammetry.

Authors:  Peng Yan; Shilin Zhang; Cunzhong Zhang; Zishuo Liu; Aidong Tang
Journal:  Mikrochim Acta       Date:  2019-10-21       Impact factor: 5.833

2.  Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Environ Monit Assess       Date:  2014-04-06       Impact factor: 2.513

3.  Electrochemical Study of Carbon Nanotubes/Nanohybrids for Determination of Metal Species Cu2+ and Pb2+ in Water Samples.

Authors:  Andréa Claudia Oliveira Silva; Luis Carlos Ferreira de Oliveira; Angladis Vieira Delfino; Mario Roberto Meneghetti; Fabiane Caxico de Abreu
Journal:  J Anal Methods Chem       Date:  2016-11-01       Impact factor: 2.193

4.  Biopolymer-Modified Carbon Paste Electrode for the Electrochemical Detection of Pb(II) in Water.

Authors:  Ousama Ifguis; Abdelaziz Moutcine; Charaf Laghlimi; Younes Ziat; Rachid Bouhdadi; Abdelilah Chtaini; Amine Moubarik; Mohamed Mbarki
Journal:  J Anal Methods Chem       Date:  2022-01-31       Impact factor: 2.193

5.  An Electrochemical Sensor of Poly(EDOT-pyridine-EDOT)/Graphitic Carbon Nitride Composite for Simultaneous Detection of Cd2+ and Pb2.

Authors:  Shuai Ding; Ahmat Ali; Ruxangul Jamal; Ling Xiang; Ziping Zhong; Tursun Abdiryim
Journal:  Materials (Basel)       Date:  2018-04-29       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.