Literature DB >> 18371712

Single drop micro-extraction with O,O-diethyl dithiophosphate for the determination of lead by electrothermal atomic absorption spectrometry.

Heloísa França Maltez1, Daniel L G Borges, Eduardo Carasek, Bernhard Welz, Adilson J Curtius.   

Abstract

Lead was extracted as the O,O-diethyldithiophosphate (DDTP) complex from aqueous solution into a drop of CHCl(3) immersed in the solution. Unlike previously reported procedures using single drop micro-extraction (SDME) for the extraction of inorganic analytes, the complexation reaction was conducted in the aqueous phase, as the ammonium salt of DDTP is soluble in water. The concentration of DDTP was optimized as 0.01% (m/v). Experimental parameters such as extraction time (7min) and organic drop volume (3microL) were optimized and selected as a compromise between sensitivity and stability of the organic drop in the aqueous solution. The sensitivity with electrothermal atomic absorption spectrometry (ET AAS) was low, probably due to infiltration of the organic drop into the totally pyrolytic graphite platform. To overcome this problem, tungsten (400microg) was thermally deposited onto the platform surface. A short pyrolysis stage at 700 degrees C was included to reduce background absorption. Under these conditions, five certified reference materials with different characteristics were analyzed using calibration against aqueous standards submitted to the SDME procedure, resulting in good agreement between certified and found concentration values at a 95% confidence level. Two real water samples have also been analyzed, with recoveries ranging from 85 to 92% after enrichment with Pb. An enhancement factor of 52 allowed a detection limit of 0.2microg L(-1) or 0.04microg g(-1), demonstrating the high detection capability of the proposed procedure, with a relative standard deviation typically below 4%.

Entities:  

Year:  2007        PMID: 18371712     DOI: 10.1016/j.talanta.2007.07.010

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Ammonium O,O'-diethyl dithio-phosphate.

Authors:  Andrzej Okuniewski; Barbara Becker
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2011-06-18

2.  Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry.

Authors:  Mahmoud Chamsaz; Jeiran Akhoundzadeh; Mohammad Hossein Arbab-Zavar
Journal:  J Adv Res       Date:  2012-12-08       Impact factor: 10.479

3.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.