Literature DB >> 18371516

Use of electronic alerts to enhance hand hygiene compliance and decrease transmission of vancomycin-resistant Enterococcus in a hematology unit.

Arjun K Venkatesh1, Mary G Lankford, Denise M Rooney, Todd Blachford, Charles M Watts, Gary A Noskin.   

Abstract

BACKGROUND: Hand hygiene (HH) compliance among health care workers (HCWs) has been historically low and hampered by poor surveillance methods. This study evaluated the use of an electronic device to measure and impact HH compliance.
METHODS: The study is a prospective, interventional study in a 30-bed academic medical center hematology unit. Phase I of the study monitored baseline HH compliance, and phase II monitored HH compliance using automatic alerts. The primary outcome measure was HH compliance, and the secondary end point was nosocomial transmission of vancomycin-resistant Enterococcus (VRE).
RESULTS: Eight thousand two hundred thirty-five HH opportunities were measured during the study, with HH compliance improvement from 36.3% at baseline to 70.1% during phase II. The use of audible alerts improved HH compliance for both the day shift (odds ratio [OR], 3.6) and the night shift (OR, 5.9), as well as across rooms with higher HCW traffic (OR, 1.6) and lower HCW traffic (OR, 3.2).
CONCLUSION: Electronic devices can effectively monitor HH compliance among HCWs and facilitate improved adherence to guidelines. Electronic devices improve HH compliance regardless of time of day or room location. The development of innovative devices to improve HH is required to validate the long-term implications of this methodology.

Entities:  

Mesh:

Year:  2008        PMID: 18371516     DOI: 10.1016/j.ajic.2007.11.005

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  17 in total

1.  Monitoring hand hygiene via human observers: how should we be sampling?

Authors:  Jason Fries; Alberto M Segre; Geb Thomas; Ted Herman; Katherine Ellingson; Philip M Polgreen
Journal:  Infect Control Hosp Epidemiol       Date:  2012-05-09       Impact factor: 3.254

2.  Increasing hand washing compliance with a simple visual cue.

Authors:  Eric W Ford; Brian T Boyer; Nir Menachemi; Timothy R Huerta
Journal:  Am J Public Health       Date:  2013-11-14       Impact factor: 9.308

3.  A systematic approach for the location of hand sanitizer dispensers in hospitals.

Authors:  Laila Cure; Richard Van Enk; Ewing Tiong
Journal:  Health Care Manag Sci       Date:  2013-11-06

4.  Hand hygiene compliance monitoring: the state of the art.

Authors:  Claudia Jarrin Tejada; Gonzalo Bearman
Journal:  Curr Infect Dis Rep       Date:  2015-04       Impact factor: 3.725

5.  Hand Hygiene: State-of-the-Art Review With Emphasis on New Technologies and Mechanisms of Surveillance.

Authors:  Alexandre R Marra; Michael B Edmond
Journal:  Curr Infect Dis Rep       Date:  2012-12       Impact factor: 3.725

6.  The precision of human-generated hand-hygiene observations: a comparison of human observation with an automated monitoring system.

Authors:  Deepti Sharma; Geb W Thomas; Eric D Foster; Jaclyn Iacovelli; Krista M Lea; Judy A Streit; Philip M Polgreen
Journal:  Infect Control Hosp Epidemiol       Date:  2012-10-25       Impact factor: 3.254

Review 7.  Assessment of Fidelity in Interventions to Improve Hand Hygiene of Healthcare Workers: A Systematic Review.

Authors:  Jackson S Musuuza; Anna Barker; Caitlyn Ngam; Lia Vellardita; Nasia Safdar
Journal:  Infect Control Hosp Epidemiol       Date:  2016-02-10       Impact factor: 3.254

8.  Rapid curbing of a vancomycin-resistant Enterococcus faecium outbreak in a nephrology department.

Authors:  Aude Servais; Lucile Mercadal; Florence Brossier; Marcia Venditto; Belkacem Issad; Corinne Isnard-Bagnis; Gilbert Deray; Jérôme Robert
Journal:  Clin J Am Soc Nephrol       Date:  2009-08-27       Impact factor: 8.237

Review 9.  The prevention and management of infections due to multidrug resistant organisms in haematology patients.

Authors:  Jason A Trubiano; Leon J Worth; Karin A Thursky; Monica A Slavin
Journal:  Br J Clin Pharmacol       Date:  2015-02       Impact factor: 4.335

10.  Investigating the use of an electronic hand hygiene monitoring and prompt device: influence and acceptability.

Authors:  Judith Dyson; Maurice Madeo
Journal:  J Infect Prev       Date:  2017-07-04
View more