Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues.

C Maleke1, E E Konofagou.   

Abstract

FUS (focused ultrasound), or HIFU (high-intensity-focused ultrasound) therapy, a minimally or non-invasive procedure that uses ultrasound to generate thermal necrosis, has been proven successful in several clinical applications. This paper discusses a method for monitoring thermal treatment at different sonication durations (10 s, 20 s and 30 s) using the amplitude-modulated (AM) harmonic motion imaging for focused ultrasound (HMIFU) technique in bovine liver samples in vitro. The feasibility of HMI for characterizing mechanical tissue properties has previously been demonstrated. Here, a confocal transducer, combining a 4.68 MHz therapy (FUS) and a 7.5 MHz diagnostic (pulse-echo) transducer, was used. The therapy transducer was driven by a low-frequency AM continuous signal at 25 Hz, producing a stable harmonic radiation force oscillating at the modulation frequency. A pulser/receiver was used to drive the pulse-echo transducer at a pulse repetition frequency (PRF) of 5.4 kHz. Radio-frequency (RF) signals were acquired using a standard pulse-echo technique. The temperature near the ablation region was simultaneously monitored. Both RF signals and temperature measurements were obtained before, during and after sonication. The resulting axial tissue displacement was estimated using one-dimensional cross correlation. When temperature at the focal zone was above 48 degrees C during heating, the coagulation necrosis occurred and tissue damage was irreversible. The HMI displacement profiles in relation to the temperature and sonication durations were analyzed. At the beginning of heating, the temperature at the focus increased sharply, while the tissue stiffness decreased resulting in higher HMI displacements. This was confirmed by an increase of 0.8 microm degrees C(-1)(r=0.93, p<.005). After sustained heating, the tissue became irreversibly stiffer, followed by an associated decrease in the HMI displacement (-0.79 microm degrees C(-1), r=-0.92, p<0.001). Repeated experiments showed a reproducible pattern of the HMI displacement changes with a temperature at a slope equal to 0.8+/-0.11 and -0.79+/-0.14 microm degrees C(-1), prior to and after lesion formation in seven bovine liver samples, respectively. This technique was thus capable of following the protein-denatured lesion formation based on the variation of the HMI displacements. This method could, therefore, be applied for real-time monitoring of temperature-related stiffness changes of tissues during FUS, HIFU or other thermal therapies.

Entities:  

Mesh:

Year:  2008        PMID: 18367802     DOI: 10.1088/0031-9155/53/6/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  38 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

3.  High intensity focused ultrasound as a tool for tissue engineering: Application to cartilage.

Authors:  Adam B Nover; Gary Y Hou; Yang Han; Shutao Wang; Grace D O'Connell; Gerard A Ateshian; Elisa E Konofagou; Clark T Hung
Journal:  Med Eng Phys       Date:  2015-12-24       Impact factor: 2.242

Review 4.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

5.  Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating.

Authors:  Linsey C Phillips; Connor Puett; Paul S Sheeran; G Wilson Miller; Terry O Matsunaga; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

6.  Thermal expansion imaging for monitoring lesion depth using M-mode ultrasound during cardiac RF ablation: in vitro study.

Authors:  Peter Baki; Sergio J Sanabria; Gabor Kosa; Gabor Szekely; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

7.  High-resolution harmonic motion imaging (HR-HMI) for tissue biomechanical property characterization.

Authors:  Teng Ma; Xuejun Qian; Chi Tat Chiu; Mingyue Yu; Hayong Jung; Yao-Sheng Tung; K Kirk Shung; Qifa Zhou
Journal:  Quant Imaging Med Surg       Date:  2015-02

8.  High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).

Authors:  Yang Han; Gary Yi Hou; Shutao Wang; Elisa Konofagou
Journal:  Phys Med Biol       Date:  2015-07-17       Impact factor: 3.609

9.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  High-resolution acoustic-radiation-force-impulse imaging for assessing corneal sclerosis.

Authors:  Cho-Chiang Shih; Chih-Chung Huang; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Med Imaging       Date:  2013-04-08       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.