Literature DB >> 18365176

The effect of overlapping on the primary stability of osteochondral grafts in mosaicplasty.

Ugur Haklar1, Tolga Tuzuner, Ilyas Uygur, Baris Kocaoglu, Osman Guven.   

Abstract

Our goal was to determine the primary stability of overlapping osteochondral grafts used in mosaicplasty by studying the effect of overlapping in an ex vivo model. Osteochondral grafts, 10 mm in diameter, were transplanted from the trochlea of cow femurs to the weight-bearing area of the lateral femoral condyle with 0, 15, or 30% overlap. The grafts were pushed in with a probe at a rate of 2 mm/min, and load (N)-displacement (mm) curves were recorded. In Group I (control, 0% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 572.3 +/- 273.6 and 999.3 +/- 427.6 N, respectively. In Group II (15% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 263.6 +/- 91.7 and 746.6 +/- 88.0 N, respectively. In Group III (30% overlap), insertion 1 and 2 mm below the cartilage level could be reached at 179.4 +/- 31.2 and 657.0 +/- 106.5 N, respectively. The loads that were necessary to produce a 1-mm dent in the grafts were significantly different between Groups I and II and Groups I and III (p < 0.05). These results suggest that stability may be reduced by graft overlapping in mosaicplasty surgery. The results of this ex vivo animal study contribute to a more complete understanding of the primary stability of osteochondral grafts in an overlapping position as well as postoperative protocols.

Entities:  

Mesh:

Year:  2008        PMID: 18365176     DOI: 10.1007/s00167-008-0526-x

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  10 in total

1.  Primary stability of press-fit-implanted osteochondral grafts. Influence of graft size, repeated insertion, and harvesting technique.

Authors:  J Duchow; T Hess; D Kohn
Journal:  Am J Sports Med       Date:  2000 Jan-Feb       Impact factor: 6.202

2.  Short-term load bearing capacity of osteochondral autografts implanted by the mosaicplasty technique: an in vitro porcine model.

Authors:  R A Whiteside; J T Bryant; R P Jakob; P Mainil-Varlet; U P Wyss
Journal:  J Biomech       Date:  2003-08       Impact factor: 2.712

Review 3.  The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens.

Authors:  F Linde; I Hvid; F Madsen
Journal:  J Biomech       Date:  1992-04       Impact factor: 2.712

4.  Primary stability of osteochondral grafts used in mosaicplasty.

Authors:  Géza Kordás; Jeno S Szabó; László Hangody
Journal:  Arthroscopy       Date:  2006-04       Impact factor: 4.772

Review 5.  Bone grafts.

Authors:  S A Martinez; T Walker
Journal:  Vet Clin North Am Small Anim Pract       Date:  1999-09       Impact factor: 2.093

6.  The effect of drill-hole length on the primary stability of osteochondral grafts in mosaicplasty.

Authors:  Géza Kordás; Jeno S Szabó; Laszló Hangody
Journal:  Orthopedics       Date:  2005-04       Impact factor: 1.390

7.  Treatment of unstable osteochondritis dissecans lesions of the knee using autogenous osteochondral grafts (mosaicplasty).

Authors:  G C Berlet; A Mascia; A Miniaci
Journal:  Arthroscopy       Date:  1999-04       Impact factor: 4.772

8.  Matrix and cell injury due to sub-impact loading of adult bovine articular cartilage explants: effects of strain rate and peak stress.

Authors:  T M Quinn; R G Allen; B J Schalet; P Perumbuli; E B Hunziker
Journal:  J Orthop Res       Date:  2001-03       Impact factor: 3.494

Review 9.  Mosaicplasty for the treatment of articular defects of the knee and ankle.

Authors:  L Hangody; P Feczkó; L Bartha; G Bodó; G Kish
Journal:  Clin Orthop Relat Res       Date:  2001-10       Impact factor: 4.176

10.  Autologous osteochondral mosaicplasty. Surgical technique.

Authors:  László Hangody; Gábor K Ráthonyi; Zsófia Duska; Gábor Vásárhelyi; Péter Füles; László Módis
Journal:  J Bone Joint Surg Am       Date:  2004-03       Impact factor: 5.284

  10 in total
  3 in total

1.  Influence of basal support and early loading on bone cartilage healing in press-fitted osteochondral autografts.

Authors:  Tomasz L Nosewicz; Mikel L Reilingh; Martin Wolny; C Niek van Dijk; Georg N Duda; Hanna Schell
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-12       Impact factor: 4.342

2.  Hexagonal grafts in mosaicplasty: Biomechanical comparison of standard cylindrical and novel hexagonal grafts in calf cadaver model.

Authors:  Adem Kar; Nihat Demirhan Demirkıran; Hasan Tatari; Bora Uzun; Fatih Ertem
Journal:  Acta Orthop Traumatol Turc       Date:  2017-03-09       Impact factor: 1.511

Review 3.  Instructive cartilage regeneration modalities with advanced therapeutic implantations under abnormal conditions.

Authors:  Zhonghan Wang; Hanxiang Le; Yanbing Wang; He Liu; Zuhao Li; Xiaoyu Yang; Chenyu Wang; Jianxun Ding; Xuesi Chen
Journal:  Bioact Mater       Date:  2021-11-18
  3 in total