The effect of drill-hole length on the primary stability of osteochondral grafts in mosaicplasty.

Géza Kordás1, Jeno S Szabó, Laszló Hangody.   

Abstract

Osteochondral grafts were transplanted from the trochlea of porcine femurs into drill holes that were 20, 15, and 12 mm in length on the lateral femoral condyle. Grafts initially were pushed in flush with the surrounding cartilage, and then a testing machine pushed the grafts 3 mm deeper. For the 20-, 15-, and 12-mm drill holes, mean forces for pushing the graft flush were 36.58, 43.33, and 118.13 N, respectively, while mean forces for pushing the graft 3 mm deeper were 122.50, 249.33, and 377.25 N, respectively. These results suggest primary stability is better when grafts and drill holes are the same length, but if the recipient hole is shorter, excessive force must be exerted on the cartilage cup during insertion.

Entities:  

Mesh:

Year:  2005        PMID: 15887587     DOI: 10.3928/0147-7447-20050401-17

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  6 in total

1.  Osteochondral transplantation using autografts from the upper tibio-fibular joint for the treatment of knee cartilage lesions.

Authors:  João Espregueira-Mendes; Hélder Pereira; Nuno Sevivas; Pedro Varanda; Manuel Vieira da Silva; Alberto Monteiro; Joaquim M Oliveira; Rui L Reis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-28       Impact factor: 4.342

2.  The effect of overlapping on the primary stability of osteochondral grafts in mosaicplasty.

Authors:  Ugur Haklar; Tolga Tuzuner; Ilyas Uygur; Baris Kocaoglu; Osman Guven
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-03-26       Impact factor: 4.342

3.  Influence of basal support and early loading on bone cartilage healing in press-fitted osteochondral autografts.

Authors:  Tomasz L Nosewicz; Mikel L Reilingh; Martin Wolny; C Niek van Dijk; Georg N Duda; Hanna Schell
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-12       Impact factor: 4.342

Review 4.  Knee donor-site morbidity after mosaicplasty - a systematic review.

Authors:  Renato Andrade; Sebastiano Vasta; Rogério Pereira; Hélder Pereira; Rocco Papalia; Mustafa Karahan; J Miguel Oliveira; Rui L Reis; João Espregueira-Mendes
Journal:  J Exp Orthop       Date:  2016-11-03

5.  Hexagonal grafts in mosaicplasty: Biomechanical comparison of standard cylindrical and novel hexagonal grafts in calf cadaver model.

Authors:  Adem Kar; Nihat Demirhan Demirkıran; Hasan Tatari; Bora Uzun; Fatih Ertem
Journal:  Acta Orthop Traumatol Turc       Date:  2017-03-09       Impact factor: 1.511

6.  Biomechanical assessment of the stability of osteochondral grafts implanted in porcine and bovine femoral condyles.

Authors:  Philippa Bowland; Raelene M Cowie; Eileen Ingham; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2019-12-04       Impact factor: 1.617

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.