Literature DB >> 18364867

Influence of Systematic Errors in Reference States on Image Quality and on Stability of Derived Information for dc Optical Imaging.

Y Pei, H L Graber, R L Barbour.   

Abstract

Optical measurements of tissue can be performed in discrete, time-averaged, and time-varying data collection modes. This information can be evaluated to yield estimates of either absolute optical coefficient values or some relative change in these values compared with a defined state. In the case of time-varying data, additional analysis can be applied to define various dynamic features. Here we have explored the accuracy with which such information can be recovered from dense scattering media using linear perturbation theory, as a function of the accuracy of the reference medium that serves as the initial guess. Within the framework of diffusion theory and a first-order solution, we have observed the following inequality regarding the sensitivity of computed measures to inaccuracy in the reference medium: Absolute measures ? relative measures > dynamic measures. In fact, the fidelity of derived dynamic measures was striking; we observed that accurate measures of dynamic behavior could be defined even if the quality of the image data from which these measures were derived was comparatively modest. In other studies we identified inaccuracy in the estimates of the reference detector values, and not to corresponding errors in the image operators, as the primary factor responsible for instability of absolute measures. The significance of these findings for practical imaging studies of tissue is discussed.

Year:  2001        PMID: 18364867     DOI: 10.1364/ao.40.005755

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  12 in total

1.  Diffuse Optics for Tissue Monitoring and Tomography.

Authors:  T Durduran; R Choe; W B Baker; A G Yodh
Journal:  Rep Prog Phys       Date:  2010-07

2.  Quantitative evaluation of atlas-based high-density diffuse optical tomography for imaging of the human visual cortex.

Authors:  Xue Wu; Adam T Eggebrecht; Silvina L Ferradal; Joseph P Culver; Hamid Dehghani
Journal:  Biomed Opt Express       Date:  2014-10-13       Impact factor: 3.732

3.  Diffuse optical tomography to measure functional changes during motor tasks: a motor imagery study.

Authors:  Estefania Hernandez-Martin; Francisco Marcano; Cristian Modroño; Niels Janssen; Jose Luis González-Mora
Journal:  Biomed Opt Express       Date:  2020-10-05       Impact factor: 3.732

4.  Comparing diffuse optical tomography and functional magnetic resonance imaging signals during a cognitive task: pilot study.

Authors:  Estefania Hernández-Martin; Francisco Marcano; Oscar Casanova; Cristian Modroño; Julio Plata-Bello; Jose Luis González-Mora
Journal:  Neurophotonics       Date:  2017-03-15       Impact factor: 3.593

5.  Digital optical tomography system for dynamic breast imaging.

Authors:  Molly L Flexman; Michael A Khalil; Rabah Al Abdi; Hyun K Kim; Christopher J Fong; Elise Desperito; Dawn L Hershman; Randall L Barbour; Andreas H Hielscher
Journal:  J Biomed Opt       Date:  2011-07       Impact factor: 3.170

6.  Somatosensory activation of two fingers can be discriminated with ultrahigh-density diffuse optical tomography.

Authors:  Christina Habermehl; Susanne Holtze; Jens Steinbrink; Stefan P Koch; Hellmuth Obrig; Jan Mehnert; Christoph H Schmitz
Journal:  Neuroimage       Date:  2011-12-01       Impact factor: 6.556

7.  High-resolution optical functional mapping of the human somatosensory cortex.

Authors:  Stefan P Koch; Christina Habermehl; Jan Mehnert; Christoph H Schmitz; Susanne Holtze; Arno Villringer; Jens Steinbrink; Hellmuth Obrig
Journal:  Front Neuroenergetics       Date:  2010-06-14

8.  Using co-variations in the Hb signal to detect visual activation: a near infrared spectroscopic imaging study.

Authors:  Glenn R Wylie; Harry L Graber; Gerald T Voelbel; Alexander D Kohl; John DeLuca; Yaling Pei; Yong Xu; Randall L Barbour
Journal:  Neuroimage       Date:  2009-05-03       Impact factor: 6.556

9.  Enhanced resting-state dynamics of the hemoglobin signal as a novel biomarker for detection of breast cancer.

Authors:  Harry L Graber; Rabah Al abdi; Yong Xu; Armand P Asarian; Peter J Pappas; Lisa Dresner; Naresh Patel; Kuppuswamy Jagarlamundi; William B Solomon; Randall L Barbour
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

10.  Contrast enhanced high-resolution diffuse optical tomography of the human brain using ICG.

Authors:  Christina Habermehl; Christoph H Schmitz; Jens Steinbrink
Journal:  Opt Express       Date:  2011-09-12       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.