Literature DB >> 18364554

Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT.

Guanghua Yan1, Chihray Liu, Bo Lu, Jatinder R Palta, Jonathan G Li.   

Abstract

The purpose of this study was to choose an appropriate head scatter source model for the fast and accurate independent planar dose calculation for intensity-modulated radiation therapy (IMRT) with MLC. The performance of three different head scatter source models regarding their ability to model head scatter and facilitate planar dose calculation was evaluated. A three-source model, a two-source model and a single-source model were compared in this study. In the planar dose calculation algorithm, in-air fluence distribution was derived from each of the head scatter source models while considering the combination of Jaw and MLC opening. Fluence perturbations due to tongue-and-groove effect, rounded leaf end and leaf transmission were taken into account explicitly. The dose distribution was calculated by convolving the in-air fluence distribution with an experimentally determined pencil-beam kernel. The results were compared with measurements using a diode array and passing rates with 2%/2 mm and 3%/3 mm criteria were reported. It was found that the two-source model achieved the best agreement on head scatter factor calculation. The three-source model and single-source model underestimated head scatter factors for certain symmetric rectangular fields and asymmetric fields, but similar good agreement could be achieved when monitor back scatter effect was incorporated explicitly. All the three source models resulted in comparable average passing rates (>97%) when the 3%/3 mm criterion was selected. The calculation with the single-source model and two-source model was slightly faster than the three-source model due to their simplicity.

Entities:  

Mesh:

Year:  2008        PMID: 18364554     DOI: 10.1088/0031-9155/53/8/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters.

Authors:  Woong Cho; Kayla N Kielar; Ed Mok; Lei Xing; Jeong-Hoon Park; Won-Gyun Jung; Tae-Suk Suh
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Efficient independent planar dose calculation for FFF IMRT QA with a bivariate Gaussian source model.

Authors:  Feifei Li; Ji-Yeon Park; Brendan Barraclough; Bo Lu; Jonathan Li; Chihray Liu; Guanghua Yan
Journal:  J Appl Clin Med Phys       Date:  2017-02-28       Impact factor: 2.102

3.  Beam flatness modulation for a flattening filter free photon beam utilizing a novel direct leaf trajectory optimization model.

Authors:  Nicholas J Potter; Guanghua Yan; Hongcheng Liu; Haitham Alahmad; Darren L Kahler; Chihray Liu; Jonathan G Li; Bo Lu
Journal:  J Appl Clin Med Phys       Date:  2020-03       Impact factor: 2.102

  3 in total