Literature DB >> 18359093

Improved performance of Brucella melitensis native hapten over Brucella abortus OPS tracer on goat antibody detection by the fluorescence polarization assay.

C Ramírez-Pfeiffer1, E Díaz-Aparicio, C Rodríguez-Padilla, A Morales-Loredo, G Alvarez-Ojeda, R Gomez-Flores.   

Abstract

The current method for goat brucellosis diagnosis is based on the World Organization for Animal Health (OIE) using the screening card test (CT), with antigen at 8% (CT8) or 3% (CT3) of cell concentrations, and the confirmatory complement fixation test (CFT). However, these tests do not differentiate antibodies induced by vaccination from those derived from field infections by Brucella species or other bacterial agents; in places like Mexico, where the prevalence of brucellosis and the vaccination rates are high, there is a considerable percentage of false positive reactions that causes significant unnecessary slaughter of animals. Furthermore, results of the fluorescence polarization assay (FPA) using the Brucella abortus O-polysaccharide (OPS) tracer in goats are poorer than those with cattle. The present study was undertaken to investigate a tracer prepared from the native hapten (NH) of the Rev. 1 strain of Brucella melitensis to improve FPA performance on goat brucellosis diagnosis. Evaluation of 48 positive samples and 96 negative samples showed that the NH tracer was more accurate (p<0.01) than the OPS tracer (97.2% vs. 93.8% accuracy, respectively). On the diagnostic performance evaluation, the NH tracer performed better (87.5% accuracy, 79.5% sensitivity, 84.3% specificity, and 163.8 performance index) than the OPS tracer (83.5%, 75.9%, 81.0%, and 156.9, respectively) using 1009 positive and 2039 negative Mexican field goat sera samples selected by test series approved by the OIE (card test 3% and CFT). We demonstrated a new application for the NH lipopolysaccharide on detecting antibodies against Brucella using the FPA, which may yield faster results (minutes vs. 24-72h) than the immunodiagnosis assays frequently used in bovine brucellosis. In addition, NH tracer produces similar or better performance results than the conventional OPS tracer, using the FPA in goat sera samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18359093     DOI: 10.1016/j.vetimm.2008.02.001

Source DB:  PubMed          Journal:  Vet Immunol Immunopathol        ISSN: 0165-2427            Impact factor:   2.046


  3 in total

1.  Evaluation of the Fluorescence Polarization Assay for the Diagnosis of Brucellosis in Goat Milk.

Authors:  Dianelys Sotolongo-Rodríguez; Ricardo Gomez-Flores; Magda Celina Navarro-Soto; Beatriz Arellano-Reynoso; Patricia Tamez-Guerra; Carlos Ramírez-Pfeiffer
Journal:  Vet Sci       Date:  2022-06-20

2.  Use of the Brucella melitensis native hapten to diagnose brucellosis in goats by a rapid, simple, and specific fluorescence polarization assay.

Authors:  Carlos Ramírez-Pfeiffer; Efrén Díaz-Aparicio; Ricardo Gomez-Flores; Cristina Rodríguez-Padilla; Alberto Morales-Loredo; Genoveva Alvarez-Ojeda
Journal:  Clin Vaccine Immunol       Date:  2008-04-02

3.  Large scale immune profiling of infected humans and goats reveals differential recognition of Brucella melitensis antigens.

Authors:  Li Liang; Diana Leng; Chad Burk; Rie Nakajima-Sasaki; Matthew A Kayala; Vidya L Atluri; Jozelyn Pablo; Berkay Unal; Thomas A Ficht; Eduardo Gotuzzo; Mayuko Saito; W John W Morrow; Xiaowu Liang; Pierre Baldi; Robert H Gilman; Joseph M Vinetz; Renée M Tsolis; Philip L Felgner
Journal:  PLoS Negl Trop Dis       Date:  2010-05-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.