Literature DB >> 18349774

Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure?

Adam J Starr1, Tetsuya Nakatani, Charles M Reinert, Kevin Cederberg.   

Abstract

OBJECTIVE: The purpose of this study is to present the early complications of percutaneous screw fixation of superior pubic ramus fractures and to present a new classification scheme for superior pubic ramus fractures.
DESIGN: Retrospective.
SETTING: Level 1 trauma center. PATIENTS: One hundred and twelve patients with pelvic fracture between the ages of 14 to 89 years underwent percutaneous screw fixation of 145 pubic ramus fractures. Eighty-one patients with 107 surgically repaired fractures were followed to fracture union. Follow-up averaged 9 months (range 2-52 months). One additional patient who sustained fixation failure 4 days after surgery was included to yield a study group of 82 patients with 108 surgically repaired ramus fractures. INTERVENTION: Patients underwent percutaneous screw fixation of a superior pubic ramus fracture. MAIN OUTCOME MEASUREMENTS: Superior pubic ramus fractures were classified according to a new scheme, the Nakatani system, which categorizes superior ramus fractures according to location with respect to the obturator foramen. Patient radiographs were examined for evidence of loss of reduction, defined as any motion at the ramus fracture site or hardware motion, after fracture surgery.
RESULTS: Of the 82 patients followed to union or fixation failure, 12 (15%) had loss of reduction on follow-up radiographs. The average age of patients who lost reduction was 55 years. The most common mechanism of reduction loss was a collapse of the pubic ramus over the screw, with recurrence of an internal rotation deformity of the injured hemipelvis. Ten patients who lost reduction were women, and 11 had undergone ramus screw placement in retrograde fashion. No loss of reduction was seen in Zone III ramus fractures (those that involve the bone lateral to the obturator foramen). No patient sustained recognized neurologic, vascular, or urologic injury as a result of percutaneous screw fixation of a superior pubic ramus fracture.
CONCLUSIONS: The prevalence of loss of reduction after percutaneous screw fixation of pubic ramus fractures is 15%. Loss of reduction is more common in elderly and female patients and in patients whose ramus screws are placed in a retrograde fashion. Also, loss of reduction appears to be more common in fractures medial to the lateral border of the obturator foramen.

Entities:  

Mesh:

Year:  2008        PMID: 18349774     DOI: 10.1097/BOT.0b013e318162ab6e

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  31 in total

1.  Volumetric analysis of corticocancellous bones using CT data.

Authors:  Dietmar Krappinger; Astrid von Linde; Ralf Rosenberger; Bernhard Glodny; Michael Blauth; Christian Niederwanger
Journal:  Skeletal Radiol       Date:  2010-12-21       Impact factor: 2.199

2.  Implementation of a standardized protocol to manage elderly patients with low energy pelvic fractures: can service improvement be expected?

Authors:  Nikolaos K Kanakaris; Tess Greven; Robert M West; Arie B Van Vugt; Peter V Giannoudis
Journal:  Int Orthop       Date:  2017-07-21       Impact factor: 3.075

3.  The obturator oblique and iliac oblique/outlet views predict most accurately the adequate position of an anterior column acetabular screw.

Authors:  João Antonio Matheus Guimarães; Murphy P Martin; Flávio Ribeiro da Silva; Maria Eugenia Leite Duarte; Amanda Dos Santos Cavalcanti; Jamila Alessandra Perini Machado; Cyril Mauffrey; David Rojas
Journal:  Int Orthop       Date:  2018-06-08       Impact factor: 3.075

4.  Assessment of Lateral Compression type 1 pelvic ring injuries by intraoperative manipulation: which fracture pattern is unstable?

Authors:  Theodoros Tosounidis; Nikolaos Kanakaris; Vasilios Nikolaou; Boon Tan; Peter V Giannoudis
Journal:  Int Orthop       Date:  2012-10-25       Impact factor: 3.075

5.  Comparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures.

Authors:  Ye Peng; Lihai Zhang; William Min; Peifu Tang
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-17       Impact factor: 2.924

6.  Anatomical study of anterior column screw tunnels through virtual three-dimensional models of the pelvis.

Authors:  Hua Chen; Peifu Tang; Yimin Yao; Fei She; Yan Wang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-11

7.  Morbidity and mortality following pelvic ramus fractures in an older Atlantic Canadian cohort

Authors:  Chris B. Hamilton; John D. Harnett; N. Craig Stone; Andrew J. Furey
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

Review 8.  Lateral compression type 1 (LC1) pelvic ring injuries: a spectrum of fracture types and treatment algorithms.

Authors:  Kenan Kuršumović; Michael Hadeed; James Bassett; Joshua A Parry; Peter Bates; Mehool R Acharya
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-04-16

9.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

10.  A radiographic simulation study of fixed superior pubic ramus fractures with retrograde screw insertion.

Authors:  Qi Quan; Lei Hong; Biao Chang; Ruo Xi Liu; Ying Qi Zhang; Qing Zhao; Shi Bi Lu
Journal:  J Orthop       Date:  2016-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.