| Literature DB >> 18339548 |
E M Souza1, S C A Correa, A X Silva, R T Lopes, D F Oliveira.
Abstract
This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images.Mesh:
Year: 2007 PMID: 18339548 DOI: 10.1016/j.apradiso.2007.11.004
Source DB: PubMed Journal: Appl Radiat Isot ISSN: 0969-8043 Impact factor: 1.513