Literature DB >> 18336900

Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology.

Anna S K Persson1, Matts Andersson, Agneta Odén, Gunilla Sandborgh-Englund.   

Abstract

OBJECTIVES: To determine the reproducibility of digitized dental stone replicas compared to the master model and the reliability of the computer aided analysis.
METHODS: Four master dies, prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). Eight vinyl polysiloxane impressions (PROVIL novo; Heraeus Kulzer) were taken of each die and stone replicas were poured in type IV stone (Vel-Mix Stone; Kerr). The master dies and the stone replicas were digitized in a touch-probe scanner (Procera Forte; Nobel Biocare AB), to create triangulated surface-models. The point-cloud from the first of the repeated digitizations of each master die was used as CAD-reference-models (CRM). Discrepancies between the points in the triangulated surface-models and the corresponding CRM were measured by a matching-software (CopyCAD 6.504 SP2; Delcam Plc). The distribution of the discrepancies was analyzed and presented in color-difference-maps.
RESULTS: The precision of the measuring method, presented as the repeatability coefficient, ranged between 7 and 16 microm (entire surface), whereas the analysis of the stone replicas revealed a precision (repeatability coefficient) ranging from 19 to 26 microm. The accuracy of the replica to master (the mean discrepancy) ranged from 0.5 to 2.0 microm (95% confidence interval 1.5-2.9 microm). SIGNIFICANCE: The greatest precision of the measurement was seen in the jacket surface of the die. The size of the stone replicas varied and the repeatability coefficient was on average 15 microm (2-25 microm) greater for the replica-to-master alignment than the repeated digitizations of the master.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18336900     DOI: 10.1016/j.dental.2008.01.008

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  15 in total

1.  Evaluation of internal and marginal fit of two metal ceramic system - in vitro study.

Authors:  Harish V; Mohamed Ali S A; Jagadesan N; Mohamed Ifthikar; Siva Senthil; Debasish Basak; Febel Huda
Journal:  J Clin Diagn Res       Date:  2014-12-05

2.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

3.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

4.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

5.  Accuracy of digital versus conventional implant impressions.

Authors:  Sang J Lee; Rebecca A Betensky; Grace E Gianneschi; German O Gallucci
Journal:  Clin Oral Implants Res       Date:  2014-04-10       Impact factor: 5.977

6.  Impact of surface roughness of gypsum materials on adaptation of zirconia cores.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Sa-Hak Kim
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

7.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

8.  Impression of multiple implants using photogrammetry: description of technique and case presentation.

Authors:  David Peñarrocha-Oltra; Rubén Agustín-Panadero; Leticia Bagán; Beatriz Giménez; María Peñarrocha
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-07-01

9.  Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner.

Authors:  Jin-Hun Jeon; Dong-Yeon Kim; Jae-Jun Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

10.  Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions.

Authors:  Tae-Gyung Kim; Sungtae Kim; Hyunmin Choi; Jae-Hoon Lee; Jae-Hong Kim; Hong-Seok Moon
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.