Structural effects of sodium hypochlorite solution on RaCe rotary nickel-titanium instruments: an atomic force microscopy study.

Ozgur Topuz1, Cumhur Aydin, Ozgur Uzun, Ugur Inan, Tayfun Alacam, Yasar M Tunca.   

Abstract

OBJECTIVE: The aim of this study was to investigate the effect of sodium hypochlorite immersion on the surface characteristics of RaCe rotary nickel-titanium instruments using atomic force microscopy (AFM). STUDY
DESIGN: Four new RaCe instruments were used in this study (two 30.06 and two 30.02). One 30.06 and one 30.02 instrument were immersed in sodium hypochlorite solution for 5 min. Surface topography of the instruments was evaluated using the AFM. The instruments were analyzed on 11 points along a 3-mm section. Root mean square (RMS) values were used to compare the topographic deviations. The data were analyzed using Student t test.
RESULTS: Mean RMS values for NaOCl measurements were higher than the measurements on new files, and the difference was statistically significant (P < .01).
CONCLUSION: The AFM results show that NaOCl causes deterioration on the surface of RaCe instruments and should be used with care during clinical use because of the risk of unexpected failure.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18329912     DOI: 10.1016/j.tripleo.2007.11.006

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  7 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Effect of NaOCl and EDTA Solutions on Topography of ESX, TruShape and ProTaper Gold NiTi Rotary Instruments - An Atomic Force Microscopic Study.

Authors:  Abhijit M Pallewar; Roopadevi Garlapati; Bolla Nagesh; Praveen Kumar Gali; Chukka Ram Sunil; Varri Sujana
Journal:  J Conserv Dent       Date:  2020-08-04

3.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

4.  The effect of 5% sodium hypochlorite, 17% EDTA and triphala on two different rotary Ni-Ti instruments: An AFM and EDS analysis.

Authors:  Pramod Siva Prasad; Jonathan Emi Sam; Arvind Kumar
Journal:  J Conserv Dent       Date:  2014-09

5.  Qualitative Assessment of the Surface Topographic Changes of XP-endo Shaper and TruNatomy files after exposure to Sodium Hypochlorite and Ethylenediaminetetraacetic Acid.

Authors:  Jerry Jose; Akshay Khandelwal; Riluwan Siddique
Journal:  Eur Endod J       Date:  2021-08

6.  The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2018-02-02

Review 7.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.