Literature DB >> 18329588

Comparison of preparation design and material thickness on microbial leakage through Cavit using a tooth model system.

Charles H Weston1, Robert D Barfield, John D Ruby, Mark S Litaker, Sandre F McNeal, Paul D Eleazer.   

Abstract

Few studies have compared Cavit thickness and access design as factors in microbial leakage. The present study used an acrylic tooth model to measure leakage of Streptococcus mutans. Pilot studies confirming the sterility of Cavit showed it will inhibit microbial growth for 2 days. The experiments compared class I preparations where Cavit thickness was 4 mm with class II preparations where thickness was 2-3 mm. Accesses sealed with cotton pellets were compared with those without cotton. Results of the study showed no bacterial contamination in any of the class I samples (up to 14 days). Some class II samples showed contamination at day 1 (3 out of 14), with all contaminated at day 7 (14 of 14), yet only 1 contaminated at day 14 (1 out of 14). The results suggest that a 4-mm thickness of Cavit should prevent bacterial ingress for at least 2 weeks, but microbial leakage may occur if temporary thickness is less than 3 mm or in a complex access preparation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18329588     DOI: 10.1016/j.tripleo.2007.10.014

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  3 in total

1.  Comparative Evaluation of Cotton PTFE Tape and Foam Pellets as Endodontic Spacer in Primary Teeth: An In Vivo Study.

Authors:  Rani Somani; M V Arya; Deepti J Singh; Shipra Jaidka; Abhraleen Chakraborty; V G Hridya
Journal:  Int J Clin Pediatr Dent       Date:  2022 Jan-Feb

Review 2.  In vitro and ex vivo microbial leakage assessment in endodontics: A literature review.

Authors:  Sohrab Tour Savadkouhi; Hengameh Bakhtiar; Safoura Emami Ardestani
Journal:  J Int Soc Prev Community Dent       Date:  2016 Nov-Dec

3.  Bacterial microleakage of temporary filling materials used for endodontic access cavity sealing.

Authors:  Igor Križnar; Katja Seme; Aleš Fidler
Journal:  J Dent Sci       Date:  2016-08-10       Impact factor: 2.080