Literature DB >> 18316504

Effect of 10% formalin on radiographic optical density of bone specimens.

A A Fonseca1, K Cherubini, E B Veeck, R S Ladeira, L P Carapeto.   

Abstract

OBJECTIVES: The aim of this work was to determine whether the fixation process with 10% formalin modifies the radiographic optical density of bone.
METHODS: Eight rabbit tibiae were placed in separate containers with one of the following fixative solutions: 10% formalin (n = 3), 10% phosphate-buffered formalin (n = 3) or 10% calcium carbonate-buffered formalin (n = 2). Radiographs were obtained at 5 different times: before fixation (time zero), then 1 day, 15 days, 30 days and 90 days following immersion in the fixative solution. Radiographs were scanned and optical density was determined using ImageTool software.
RESULTS: There was no significant difference in radiographic optical density among the specimens fixed in 10% formalin (146.60+/-32.44), 10% phosphate-buffered formalin (149.84+/-32.43) and 10% calcium carbonate-buffered formalin (146.61+/-35.92). Regardless of buffering, optical density at time zero was significantly higher than that at 15 days, 30 days and 90 days. However, while optical density at 1 day was significantly higher than that at 30 days and 90 days, it did not differ from that at 15 days. There was also no significant difference in density between 30 days and 90 days (ANOVA, Tukey, at 5% level of significance).
CONCLUSION: The radiographic optical density of specimens stored in 10% formalin diminishes with time, irrespective of buffering, which suggests the occurrence of bone demineralization.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18316504     DOI: 10.1259/dmfr/18109064

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  9 in total

Review 1.  Human body preservation - old and new techniques.

Authors:  Erich Brenner
Journal:  J Anat       Date:  2014-01-18       Impact factor: 2.610

2.  Does formalin fixation influence MSCT/CBCT accuracy?

Authors:  Anna Seidel; Bastian Bergauer; Michael Lell; Thomas Buder; Cornelius von Wilmowsky; Eva Dach; Manfred Wichmann; Ragai-Edward Matta
Journal:  Surg Radiol Anat       Date:  2017-08-21       Impact factor: 1.246

3.  Systematic Radiation Dose Reduction in Cervical Spine CT of Human Cadaveric Specimens: How Low Can We Go?

Authors:  M Tozakidou; C Reisinger; D Harder; J Lieb; Z Szucs-Farkas; M Müller-Gerbl; U Studler; S Schindera; A Hirschmann
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-21       Impact factor: 3.825

4.  Radiographic sclerotic contour loss in the identification of glenoid bone loss.

Authors:  Troy D Bornes; Jacob L Jaremko; Lauren A Beaupre; Martin J Bouliane
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

5.  Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system.

Authors:  Karsten Sebastian Luetkens; Süleyman Ergün; Henner Huflage; Andreas Steven Kunz; Carsten Herbert Gietzen; Nora Conrads; Lenhard Pennig; Lukas Goertz; Thorsten Alexander Bley; Tobias Gassenmaier; Jan-Peter Grunz
Journal:  Sci Rep       Date:  2021-10-11       Impact factor: 4.379

6.  Metal artifact reduction in ultra-high-resolution cone-beam CT imaging with a twin robotic X-ray system.

Authors:  Andreas Steven Kunz; Theresa Sophie Patzer; Jan-Peter Grunz; Karsten Sebastian Luetkens; Viktor Hartung; Robin Hendel; Tabea Fieber; Franca Genest; Süleyman Ergün; Thorsten Alexander Bley; Henner Huflage
Journal:  Sci Rep       Date:  2022-09-16       Impact factor: 4.996

7.  One-stop-shop CT arthrography of the wrist without subject repositioning by means of gantry-free cone-beam CT.

Authors:  Karsten Sebastian Luetkens; Jan-Peter Grunz; Mila Marie Paul; Henner Huflage; Nora Conrads; Theresa Sophie Patzer; Philipp Gruschwitz; Süleyman Ergün; Thorsten Alexander Bley; Andreas Steven Kunz
Journal:  Sci Rep       Date:  2022-08-24       Impact factor: 4.996

8.  3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT.

Authors:  Jan-Peter Grunz; Andreas Max Weng; Andreas Steven Kunz; Maike Veyhl-Wichmann; Rainer Schmitt; Carsten Herbert Gietzen; Lenhard Pennig; Stefan Herz; Süleyman Ergün; Thorsten Alexander Bley; Tobias Gassenmaier
Journal:  Eur Radiol Exp       Date:  2020-09-08

9.  In vivo regeneration functionalities of experimental organo-biomaterials containing water-soluble nacre extract.

Authors:  João César Zielak; David Gulin Neto; Makeli Aparecida Cazella Zielak; Leonardo Brunet Savaris; Fernando Luis Esteban Florez; Tatiana Miranda Deliberador
Journal:  Heliyon       Date:  2018-09-14
  9 in total