Literature DB >> 18313599

Consistency of complex fractionated atrial electrograms during atrial fibrillation.

Yenn-Jiang Lin1, Ching-Tai Tai, Tsair Kao, Shih-Lin Chang, Wanwarang Wongcharoen, Li-Wei Lo, Ta-Chuan Tuan, Ameya R Udyavar, Yi-Jen Chen, Satoshi Higa, Kuo-Chang Ueng, Shih-Ann Chen.   

Abstract

BACKGROUND: Temporal variation in complex fractionated atrial electrograms (CFAEs) exists during atrial fibrillation (AF).
OBJECTIVE: This study sought to quantify the variation in CFAEs using a fractionation interval (FI) algorithm and to define the shortest optimal recording duration required to consistently characterize the magnitude of the fractionation.
METHODS: Twenty-seven patients undergoing AF mapping in the left atrium were studied. The FI and frequency analysis were performed at each mapped site for recording durations of 1 to 8 seconds. The magnitude of the fractionation was quantified by the FI algorithm, which calculated the mean interval between multiple, discrete deflections during AF. The results from each duration were statistically compared with the maximal-duration recording, as a standard. The FI values were compared with the dominant frequency values obtained from the associated frequency spectra.
RESULTS: The FIs obtained from recording durations between 5 and 8 seconds had a smaller variation in the FI (P < .05) and, for those sites with a FI < 50 ms, the fractionation was typically continuous. The fast-Fourier Transform spectra obtained from the CFAE sites with recording durations of >5 seconds harbored higher dominant frequency values than those with shorter recording durations (8.1 +/- 2.5 Hz vs. 6.8 +/- 0.98 Hz, P < .05). The CFAE sites with continuous fractionation were located within the pulmonary veins and their ostia in 77% of patients with paroxysmal AF, and in only 29% of patients with nonparoxysmal AF (P < .05).
CONCLUSION: The assessment of fractionated electrograms requires a recording duration of > or =5 seconds at each site to obtain a consistent fractionation. Sites with the shortest FIs consistently identified sites with the fastest electrogram activity throughout the entire left atrium and pulmonary veins.

Entities:  

Mesh:

Year:  2008        PMID: 18313599     DOI: 10.1016/j.hrthm.2007.12.009

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  24 in total

Review 1.  Source Determination in Atrial Fibrillation.

Authors:  Rakesh Latchamsetty; Fred Morady
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 2.  The Role of Atrial Structural Remodeling in Atrial Fibrillation Ablation:An Imaging Point of View for Predicting Recurrence.

Authors:  Yasushi Akutsu; Kaoru Tanno; Youichi Kobayashi
Journal:  J Atr Fibrillation       Date:  2012-08-20

Review 3.  Differences of BiAtrial Substrate Properties in Patients with Different Types of AF.

Authors:  Kazuyoshi Suenari; Hidekazu Hirao; Mitsunori Okamoto; Yasuki Kihara; Shih-Ann Chen
Journal:  J Atr Fibrillation       Date:  2012-12-16

Review 4.  Trigger Versus Substrate Ablation for Atrial Fibrillation.

Authors:  Atul Verma
Journal:  J Atr Fibrillation       Date:  2008-07-16

Review 5.  Catheter Ablation Targeting Complex Fractionated Atrial Electrogram in Atrial Fibrillation.

Authors:  Dennis H Lau; Stef Zeemering; Bart Maesen; Pawel Kuklik; Sander Verheule; Ulrich Schotten
Journal:  J Atr Fibrillation       Date:  2013-10-31

6.  Long-term clinical outcome and risk of catheter ablation in elderly with non-paroxysmal atrial fibrillation.

Authors:  Liquan Dong; Zidong Bie; Liye Sun; Xudong Pan; Lijuan Guo
Journal:  Int J Clin Exp Med       Date:  2015-09-15

Review 7.  Addressing challenges of quantitative methodologies and event interpretation in the study of atrial fibrillation.

Authors:  Edward J Ciaccio; Elaine Y Wan; Deepak S Saluja; U Rajendra Acharya; Nicholas S Peters; Hasan Garan
Journal:  Comput Methods Programs Biomed       Date:  2019-06-15       Impact factor: 5.428

8.  Differences in repeating patterns of complex fractionated left atrial electrograms in longstanding persistent atrial fibrillation as compared with paroxysmal atrial fibrillation.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; John A Vest; Alok Gambhir; Andrew J Einstein; Hasan Garan
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-05-02

9.  Substrate and Trigger Ablation for Reduction of Atrial Fibrillation (STAR AF): a randomized, multicentre, international trial.

Authors:  Atul Verma; Roberto Mantovan; Laurent Macle; Guiseppe De Martino; Jian Chen; Carlos A Morillo; Paul Novak; Vittorio Calzolari; Peter G Guerra; Girish Nair; Esteban G Torrecilla; Yaariv Khaykin
Journal:  Eur Heart J       Date:  2010-03-09       Impact factor: 29.983

10.  Spatial and temporal variability of the complex fractionated atrial electrogram activity and dominant frequency in human atrial fibrillation.

Authors:  Rikitake Kogawa; Yasuo Okumura; Ichiro Watanabe; Masayoshi Kofune; Koichi Nagashima; Hiroaki Mano; Kazumasa Sonoda; Naoko Sasaki; Kimie Ohkubo; Toshiko Nakai; Atsushi Hirayama
Journal:  J Arrhythm       Date:  2014-09-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.