Literature DB >> 18307999

Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting.

Tetsu Yamaguchi1, Mitsuyasu Terashima, Takashi Akasaka, Takahiro Hayashi, Kyoichi Mizuno, Toshiya Muramatsu, Masato Nakamura, Shigeru Nakamura, Satoshi Saito, Masamichi Takano, Tadateru Takayama, Junichi Yoshikawa, Takahiko Suzuki.   

Abstract

Optical coherence tomography (OCT) is a fiber-optic technology that enables high-resolution intracoronary imaging. The aim of this study was to evaluate the safety and feasibility of intracoronary imaging with OCT in the clinical setting; 76 patients with coronary artery disease from 8 centers were enrolled. The OCT imaging system (ImageWire, Light Imaging Inc., Westford, Massachusetts) consists of a 0.006 inch fiber-optic core that rotates within a 0.016 inch transparent sheath. OCT imaging was performed during occlusion of the artery with a compliant balloon and continuous flushing. Intravascular ultrasound (IVUS) imaging was performed in the same segments. We assessed the safety and feasibility of the OCT imaging, compared with IVUS. Vessel occlusion time was 48.3 +/- 13.5 seconds and occlusion-balloon pressure was 0.4 +/- 0.1 atmospheres. Flushing with lactated Ringer's solution was performed at a rate of 0.6 +/- 0.4 ml/s. No significant adverse events, including vessel dissection or fatal arrhythmia, were observed. Procedural success rates were 97.3% by OCT and 94.5% by IVUS. The OCT image wire was able to cross 5 of 6 tight lesions that the IVUS catheter was unable to cross. Of the 98 lesions in which both OCT and IVUS were successfully performed, OCT imaging had an advantage over IVUS for visualization of the lumen border. Minimum lumen diameter and area measurements were significantly correlated between OCT and IVUS imaging (r = 0.91, p <0.0001 and r = 0.95, p <0.0001, respectively). In conclusion, this multicenter study demonstrates the safety and feasibility of OCT imaging in the clinical setting.

Entities:  

Mesh:

Year:  2008        PMID: 18307999     DOI: 10.1016/j.amjcard.2007.09.116

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  27 in total

1.  Dual-element needle transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Min Gon Kim; Jay A Williams; Changhan Yoon; Bong Jin Kang; Nestor Cabrera-Munoz; K Kirk Shung; Hyung Ham Kim
Journal:  J Med Imaging (Bellingham)       Date:  2015-04-13

Review 2.  Interventional molecular imaging.

Authors:  Xiaoming Yang
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

Review 3.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

4.  Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction: the IBIS-4 (integrated biomarker and imaging study) substudy.

Authors:  Masanori Taniwaki; Maria D Radu; Hector M Garcia-Garcia; Dik Heg; Henning Kelbæk; Lene Holmvang; Aris Moschovitis; Stephane Noble; Giovanni Pedrazzini; Kari Saunamäki; Jouke Dijkstra; Ulf Landmesser; Peter Wenaweser; Bernhard Meier; Giulio G Stefanini; Marco Roffi; Thomas F Lüscher; Stephan Windecker; Lorenz Räber
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-28       Impact factor: 2.357

5.  Optical coherence tomography in STEMI with bioresorbable scaffold: possible cause of coronary flow impairment? A sub-study from the Prague 19 trial.

Authors:  Marco Loffi; Petr Tousek; Tomas Budesinsky; Libor Lisa; Andrea Santangelo; Petr Widimsky; Viktor Kocka
Journal:  Heart Vessels       Date:  2018-05-18       Impact factor: 2.037

6.  In vivo comparison of lumen dimensions measured by time domain-, and frequency domain-optical coherence tomography, and intravascular ultrasound.

Authors:  Soo-Joong Kim; Hang Lee; Koji Kato; Taishi Yonetsu; Ik-Kyung Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-06       Impact factor: 2.357

7.  The ecosystem that powered the translation of OCT from fundamental research to clinical and commercial impact [Invited].

Authors:  Eric A Swanson; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

Review 8.  Concise Review of Optical Coherence Tomography in Clinical Practice.

Authors:  Min-I Su; Chun-Yen Chen; Hung-I Yeh; Kuang-Te Wang
Journal:  Acta Cardiol Sin       Date:  2016-07       Impact factor: 2.672

9.  Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Jay Williams; Bong Jin Kang; Changhan Yoon; Nestor Cabrera-Munoz; Jong Seob Jeong; Sang Goo Lee; K Kirk Shung; Hyung Ham Kim
Journal:  Sens Actuators A Phys       Date:  2015-06-01       Impact factor: 3.407

Review 10.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications.

Authors:  Hiram G Bezerra; Marco A Costa; Giulio Guagliumi; Andrew M Rollins; Daniel I Simon
Journal:  JACC Cardiovasc Interv       Date:  2009-11       Impact factor: 11.195

View more