Literature DB >> 18307630

How revealing are insertable loop recorders in pediatrics?

Patricia A Frangini1, Frank Cecchin, Ligia Jordao, Maria Martuscello, Mark E Alexander, John K Triedman, Edward P Walsh, Charles I Berul.   

Abstract

INTRODUCTION: An insertable loop recorder (ILR) in patients with infrequent syncope or palpitations may be useful to decide management strategies, including clinical observation, medical therapy, pacemaker, or implantable cardioverter defibrillator (ICD). We sought to determine the diagnostic utility of the Reveal ILR (Medtronic, Inc., Minneapolis, MN, USA) in pediatric patients.
METHODS: Retrospective review of clinical data, indications, findings, and therapeutic decision in 27 consecutive patients who underwent ILR implantation from 1998-2007.
RESULTS: The median age was 14.8 years (2-25 years). Indications were syncope in 24 patients and recurrent palpitations in three. Overall, eight patients had structural heart disease (six congenital heart disease, one hypertrophic cardiomyopathy, one Kawasaki), five had previous documented ventricular arrhythmias with negative evaluation including electrophysiology study, and three patients had QT prolongation. Tilt testing was performed in 10 patients, of which five had neurocardiogenic syncope but recurrent episodes despite medical therapy. After median three months (1-20 months), 17 patients presented with symptoms and the ILR memory was analyzed in 16 (no episode stored in one due to full device memory), showing asystole or transient atrioventricular (AV) block (2), sinus bradycardia (6), or normal sinus rhythm (8). Among asymptomatic patients, 3/10 had intermittent AV block or long pauses, automatically detected and stored by the ILR. In 19 of 20 patients, ILR was diagnostic (95%) and five subsequently underwent pacemaker implantation, while seven patients remained asymptomatic without ILR events. Notably, no life-threatening events were detected. The ILR was explanted in 22 patients after a median of 22 months, two due to pocket infection, 12 for battery depletion and eight after clear documentation of nonmalignant arrhythmia.
CONCLUSIONS: The ILR in pediatrics is a useful adjunct to other diagnostic studies. Patient selection is critical as the ILR should not be utilized for malignant arrhythmias. A diagnosis is attained in the majority of symptomatic patients, predominantly bradyarrhythmias including pauses and intermittent AV block.

Entities:  

Mesh:

Year:  2008        PMID: 18307630     DOI: 10.1111/j.1540-8159.2008.00995.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  16 in total

1.  [Significance of diagnostic methods in the work-up of syncope].

Authors:  C Strotmann; N Rüb; C Wolpert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-06

2.  Placement of Reveal LINQ Device in the Left Anterior Axillary Position.

Authors:  Heather Anderson; Joseph Dearani; M Yasir Qureshi; Kimberly Holst; Patrick O'Leary; Bryan Cannon; Philip Wackel
Journal:  Pediatr Cardiol       Date:  2019-11-19       Impact factor: 1.655

3.  PocketECG: A New Noninvasive Method for Continuous and Real-Time ECG Monitoring-Initial Results in Children and Adolescents.

Authors:  Katarzyna Bieganowska; Agnieszka Kaszuba; Maciej Bieganowski; Krzysztof Kaczmarek
Journal:  Pediatr Cardiol       Date:  2017-01-18       Impact factor: 1.655

Review 4.  [Event-recorder].

Authors:  Andreas Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-10-25

5.  Holter Monitoring and Loop Recorders: From Research to Clinical Practice.

Authors:  Alessio Galli; Francesco Ambrosini; Federico Lombardi
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

6.  Using a Cardiac Event Recorder in Children with Potentially Arrhythmia-Related Symptoms.

Authors:  Murat Saygi; Yakup Ergul; Isa Ozyilmaz; Fatma Sevinc Sengul; Osman Guvenc; Eyup Aslan; Alper Guzeltas; Celal Akdeniz; Volkan Tuzcu
Journal:  Ann Noninvasive Electrocardiol       Date:  2016-01-21       Impact factor: 1.468

7.  Idiopathic ventricular arrhythmias detected by an implantable loop recorder in a child with exercise-induced syncope.

Authors:  Celal Akdeniz; Isa Ozyilmaz; Murat Saygi; Yakup Ergul; Volkan Tuzcu
Journal:  Tex Heart Inst J       Date:  2013

Review 8.  Common syndromes of orthostatic intolerance.

Authors:  Julian M Stewart
Journal:  Pediatrics       Date:  2013-04-08       Impact factor: 7.124

Review 9.  Evaluation and management of bradycardia in neonates and children.

Authors:  Alban-Elouen Baruteau; James C Perry; Shubhayan Sanatani; Minoru Horie; Anne M Dubin
Journal:  Eur J Pediatr       Date:  2016-01-16       Impact factor: 3.860

10.  Clinical symptoms associated with asystolic or bradycardic responses on implantable loop recorder monitoring in patients with recurrent syncope.

Authors:  Khalil Kanjwal; Yousuf Kanjwal; Beverly Karabin; Blair P Grubb
Journal:  Int J Med Sci       Date:  2009-04-09       Impact factor: 3.738