Ultra-fast and accurate assessment of cardiac function in rats using accelerated MRI at 9.4 Tesla.

Jürgen E Schneider1, Titus Lanz, Hannah Barnes, Debra Medway, Lee-Anne Stork, Craig A Lygate, Sean Smart, Mark A Griswold, Stefan Neubauer.   

Abstract

MRI can accurately and reproducibly assess cardiac function in rodents but requires relatively long imaging times. Therefore, parallel imaging techniques using a 4-element RF-coil array and MR sequences for cardiac MRI in rats were implemented at ultra-high magnetic fields (9.4 Tesla [T]). The hypothesis that these developments would result in a major reduction in imaging time without loss of accuracy was tested on female Wistar rats under isoflurane anesthesia. High-resolution, contiguous short-axis slices (thickness 1.5 mm) were acquired covering the entire heart. Two interleaved data sets (i) with the volume coil (eight averages) and (ii) with the four-element coil array (one average) were obtained. In addition, two-, three-, and fourfold accelerated data sets were generated through postprocessing of the coil array data, followed by a TGRAPPA reconstruction, resulting in five data sets per rat (in-plane voxel size 100 x 100 microm). Using a single blinded operator, excellent agreement was obtained between volume coil (acquisition time: 88 min) and the fourfold accelerated (<3 min) data sets (e.g., LV mass 436 +/- 21 mg vs 433 +/- 19 mg; ejection fraction 74 +/- 5% vs 75 +/- 4%). This finding demonstrates that it is possible to complete a rat cine-MRI study under 3 min with low variability and without losing temporal or spatial resolution, making high throughput screening programs feasible. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18306411     DOI: 10.1002/mrm.21491

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Multiple-mouse MRI with multiple arrays of receive coils.

Authors:  Marc S Ramirez; Emilio Esparza-Coss; James A Bankson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

2.  A parallel imaging approach to wide-field MR microscopy.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

3.  A 20-channel receive-only mouse array coil for a 3 T clinical MRI system.

Authors:  Boris Keil; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald; Florian M Meise; Laura M Schreiber; Klaus J Klose; Johannes T Heverhagen
Journal:  Magn Reson Med       Date:  2011-03-23       Impact factor: 4.668

4.  Accelerated cardiovascular magnetic resonance of the mouse heart using self-gated parallel imaging strategies does not compromise accuracy of structural and functional measures.

Authors:  David Ratering; Christof Baltes; Carola Dörries; Markus Rudin
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-21       Impact factor: 5.364

5.  Noninvasive monitoring of HPMA copolymer-RGDfK conjugates by magnetic resonance imaging.

Authors:  Bahar Zarabi; Mark P Borgman; Jiachen Zhuo; Rao Gullapalli; Hamidreza Ghandehari
Journal:  Pharm Res       Date:  2009-01-22       Impact factor: 4.200

6.  Rapid assessment of myocardial infarct size in rodents using multi-slice inversion recovery late gadolinium enhancement CMR at 9.4T.

Authors:  Anthony N Price; King K Cheung; Shiang Y Lim; Derek M Yellon; Derek J Hausenloy; Mark F Lythgoe
Journal:  J Cardiovasc Magn Reson       Date:  2011-09-05       Impact factor: 5.364

7.  Accelerating cine-MR imaging in mouse hearts using compressed sensing.

Authors:  Tobias Wech; Angela Lemke; Debra Medway; Lee-Anne Stork; Craig A Lygate; Stefan Neubauer; Herbert Köstler; Jürgen E Schneider
Journal:  J Magn Reson Imaging       Date:  2011-09-19       Impact factor: 4.813

8.  Development of Real-Time Magnetic Resonance Imaging of Mouse Hearts at 9.4 Tesla--Simulations and First Application.

Authors:  Tobias Wech; Nicole Seiberlich; Andreas Schindele; Vicente Grau; Leonie Diffley; Michael L Gyngell; Alfio Borzì; Herbert Köstler; Jurgen E Schneider
Journal:  IEEE Trans Med Imaging       Date:  2015-11-19       Impact factor: 10.048

9.  Long-term left ventricular remodelling in rat model of nonreperfused myocardial infarction: sequential MR imaging using a 3T clinical scanner.

Authors:  Muhammad G Saleh; Sarah-Kate Sharp; Alkathafi Alhamud; Bruce S Spottiswoode; Andre J W van der Kouwe; Neil H Davies; Thomas Franz; Ernesta M Meintjes
Journal:  J Biomed Biotechnol       Date:  2012-10-04

10.  Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla.

Authors:  Jürgen E Schneider; Titus Lanz; Hannah Barnes; Lee-Anne Stork; Steffen Bohl; Craig A Lygate; Roger J Ordidge; Stefan Neubauer
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.