Long-term electroencephalographic (EEG) recordings are important in the presurgical evaluation of refractory partial epilepsy for the delineation of the ictal onset zones. In this paper, we introduce a new concept for an automatic, fast, and objective localisation of the ictal onset zone in ictal EEG recordings. Canonical decomposition of ictal EEG decomposes the EEG in atoms. One or more atoms are related to the seizure activity. A single dipole was then fitted to model the potential distribution of each epileptic atom. In this study, we performed a simulation study in order to estimate the dipole localisation error. Ictal dipole localisation was very accurate, even at low signal-to-noise ratios, was not affected by seizure activity frequency or frequency changes, and was minimally affected by the waveform and depth of the ictal onset zone location. Ictal dipole localisation error using 21 electrodes was around 10.0 mm and improved more than tenfold in the range of 0.5-1.0 mm using 148 channels. In conclusion, our simulation study of canonical decomposition of ictal scalp EEG allowed a robust and accurate localisation of the ictal onset zone.
Long-term electroencephalographic (EEG) recordings are important in the presurgical evaluation of refractory partial epilepsy for the delineation of the ictal onset zones. In this paper, we introduce a new concept for an automatic, fast, and objective localisation of the ictal onset zone in ictal EEG recordings. Canonical decomposition of ictal EEG decomposes the EEG in atoms. One or more atoms are related to the seizure activity. A single dipole was then fitted to model the potential distribution of each epileptic atom. In this study, we performed a simulation study in order to estimate the dipole localisation error. Ictal dipole localisation was very accurate, even at low signal-to-noise ratios, was not affected by seizure activity frequency or frequency changes, and was minimally affected by the waveform and depth of the ictal onset zone location. Ictal dipole localisation error using 21 electrodes was around 10.0 mm and improved more than tenfold in the range of 0.5-1.0 mm using 148 channels. In conclusion, our simulation study of canonical decomposition of ictal scalp EEG allowed a robust and accurate localisation of the ictal onset zone.
Epilepsy is one
of the most common, severe neurological diseases. People suffering from
epilepsy, who are not helped by medication, can potentially benefit from
epilepsy surgery [1]. In order to remove the epileptogenic region, a
precise localisation of the epileptic focus is mandatory. One of the diagnostic
tools to localize this region of seizure onset zone is recording of ictal scalp
electroencephalogram (EEG) [2]. The EEG measures electric potential distributions at
discrete recording sites on the scalp. These potential distributions are the
direct consequence of internal electrical currents associated with the
synchronous firing of neurons. EEG recordings have an excellent temporal
resolution, but a rather poor spatial accuracy due to the limited number of
recording sites and the shielding effect of the skull. Visual analysis of EEG
recordings aims to determine which lobe or which electrodes are activated. A
challenging problem in neuroscience is to estimate in a more objective and
precise way the regions of the brain that are active, given only the measured
potential distributions.Estimating the electrical source in the brain from the
scalp EEG is a difficult problem since an infinite number of internal
electrical currents can generate the same potential distribution on the scalp.
Several different approaches to solve this source localisation or inverse
problem exist based on different assumptions [3, 4]. One assumption is that the surface potentials are
generated by a dense set of dipolar sources distributed on the cortical
surface. The most popular method from this “distributed source”
family is Loreta [5]. In a second approach, which is the most common, a
limited number of “equivalent dipoles” are assumed to generate the
measured potential distribution [6]. Dipole modeling is a well-established technique for
localising interictal spikes, see, for example, [7, 8] and references herein. Ictal EEG recordings have been
subjected to dipole modeling much less often than interictal spikes. The
seizure discharge is a very complex pattern. Mainly artifacts, such as
electromyogram, movement, eye blinks, and eye movements artifacts, render
modeling difficult [9]. Even visual analysis of seizure onset can be
significantly improved by removing muscle artifacts [10]. Moreover, the low signal-to-noise ratio of the
seizure signal can render the correct localisation very diffuse. However, when
source localisation of seizure onset would be possible, it can reduce the need
for invasive intracranial EEG recordings. So far, the results of ictal EEG
source localisation have been discouraging. One study reports that the used
“inverse solution” [11] is not useful at all for localising seizure onsets [12]. Some studies were restricted to temporal lobe
seizures [13, 14]. One reason to select temporal lobe seizures is that
source analysis is most reliable during periods of relative signal stationarity
in order to average repetitive ictal waveforms, which is more common in
temporal than in extratemporal lobe seizures. Another reason for selecting only
temporal lobe seizures is that extratemporal lobe seizures are much more
frequently contaminated by severe artifacts. Two other studies were not
restricted to temporal lobe seizures. Gotman [9] obtained reliable models for seizure onset in 6 out
of 15 patients (40%) and Boon et al. [15] in 31 out of 100 patients (31%). In the latter study,
the ictal EEG was filtered with a narrowband filter (1–14 Hz), while ictal
seizure activity is known to consist of rhythmical waves with a frequency
between 3 and 29 Hz [16]. Filtering should be avoided because these filters
suppress all high-frequency activity, including electrical brain activity.
Moreover, muscle artifacts filtered by a lowpass filter can resemble cerebral
activity [17]. All these studies illustrate how difficult it is to
reliably estimate ictal sources, and indicate that the current ictal scalp EEG
source analysis tools can not be used for a reliable localisation of the ictal
onset zone during presurgical evaluation. A recent study on source analysis
developed a novel integrative approach to characterise the structure of
seizures in the space, time, and frequency domains and showed some promising
results [18].The localising value of dipole modeling of ictal EEG
can be improved by first removing artifacts and afterwards estimating the sources
[19]. Another possibility is to decompose the measured EEG
in a sum of individual contributions of distinct brain sources and localising
the epilepsy-related source in order to estimate the epileptic focus. Space-time
decomposition techniques like principal component analysis (PCA) and
independent component analysis (ICA) of multichannel EEG can be used for
artifact removal [20, 21] or for extracting activities of interest [22, 23]. However, in order to obtain a matrix decomposition
like PCA and ICA, assumptions like orthogonality or independence—which are
physically maybe irrelevant—have to be imposed. Recently, we have shown that
a space-time-frequency decomposition of a three-way array containing wavelet-transformed EEG by the canonical decomposition (Candecomp), also known as
parallel factor analysis (Parafac), reliably separated a seizure atom from the
noise and background activity with a sensitivity of more than 90% [24]. This work was inspired by [25, 26]. The main advantage of this decomposition is that no
extra assumptions have to be imposed. After the decomposition, the potential
distribution over the electrodes of the epilectical activity was obtained, and
displayed as a 2D image. Electrodes with large potential amplitudes could be
considered as close to the focus. The aim of the present study was twofold.
First, we wanted to investigate whether it was possible to localise the ictal
onset zone in the head by applying dipole source localisation after canonical
decomposition of ictal EEG recordings. Second, we wanted to investigate the
accuracy of this localising method with realistic simulations under different
conditions. We were especially interested (i) in the influence of the frequency
of the seizure activity on the localisation, (ii) how the dipole localisation
would be influenced by changes in frequency, and (iii) if the dipole estimation
accuracy could be improved by increasing the number of electrodes.We start by revising the canonical decomposition of a
higher-order array (Section 2.1). We then define how we constructed realistically
simulated EEG (Section 2.2), assessed the accuracy of our method (Section 3)
and finally discuss our results (Section 4).
2. MATERIALS AND METHODS
2.1. Method
In our application, a three-way data array with dimensions
(space, scale, time) is obtained by wavelet-transforming every channel of the
original (or simulated) EEG matrix. The continuous wavelet transform at scale and time of a signal is defined as
with the chosen
wavelet. Different real wavelets can be used. In this study, we used a
biorthogonal wavelet with decomposition order 3. From the scale of the wavelet,
the frequency of the signal
can be estimated as
with the center
frequency of the wavelet and the sampling
period.The trilinear Candecomp [27-29] is a generalisation of the singular value
decomposition (SVD) for higher orders. It is defined for a three-way array as
where is the
number of components used in the Candecomp model and are the
residuals containing the unexplained variation. A pictorial representation of
the Candecomp model is given in Figure 1. The Candecomp model is a trilinear model: fixing the
parameters in two modes, is expressed as
a linear function of the remaining parameters. Another equivalent and useful expression of the same Candecomp model is
given with the Khatri-Rao product , defined as the column-wise Kronecker product [30].
Figure 1
The Candecomp model with components.
Stack the elements of the tensor in a matrix as
Construct a matrix in a similar
way. Collect the elements in ; in and in . ThenComparing the number of free parameters of a generic
tensor and a Candecomp model, it can be seen that this model is very
restricted. The advantage of this model is its uniqueness under mild conditions
[31-33]:
with the -rank of matrix . The -rank of matrix is defined as
the maximal number such that any
set of columns of is linearly
independent. For tensors of which one dimension is greater than the rank,
another less restrictive condition has recently been derived in [34].The canonical decomposition is usually computed by
means of an alternating least-squares (ALS) algorithm [30].
This means that the least-squares cost function
is minimized by means of alternating updates of one of
its matrix arguments, keeping the other two matrices fixed. Because the
canonical decomposition is a multilinear decomposition, each update just
amounts to solving a classical linear least-squares problem. The convergence
may be local. To increase the probability that the global minimum is found, the
algorithm is reinitialized a couple of times. Since the introduction of the ALS
algorithm, other computational schemes have been proposed [34-37].When Candecomp is used for seizure localisation, 2
seconds of EEG at the seizure onset is wavelet transformed. The obtained
three-way array is decomposed with Candecomp with atoms. Several
techniques exist to determine the optimal number of atoms [30]. Corcondia was used to determine the optimal number
of atoms . After decomposition, each atom has a component in
the space (), time (), and frequency domain (). The seizure atom(s) can be selected based on
characteristic signatures in the different domains. At the ictal onset, seizure
activity is recognised by rhythmical activity that is well localised in space
and frequency. This was also described in [38]. Another possibility is to reconstruct the decomposed
atoms in EEG settings by means of the inverse continuous wavelet transform
(ICWT) [39]. We illustrate this approach with an example. EEG
containing clear ictal activity in the right temporal lobe is given in Figure 2. The seizure starts at Second 3, and the EEG between
Second 3 and 5 is wavelet transformed and decomposed with Candecomp (see Figure 3). Corcondia indicated that a decomposition in two
atoms would be appropriate. The first atom is recognized as seizure atom. The
frequency component peaks around 3 Hz and the time component is a rhythmical
waveform that increases in amplitude. When this component is reconstructed in
EEG settings, pure ictal activity can be seen (see Figure 4). Because the atoms in the canonical decomposition
have a very simple, trilinear structure, we propose to fit only 1 dipole for
every atom. We expect that, when a patient suffers from multifocal epilepsy,
different atoms will be related to activity generated by the different dipoles.
Figure 2
10 seconds of EEG containing the start of
a seizure.
Figure 3
Seconds 3 to 5 of the
seizure shown in Figure 2 are decomposed with the canonical
decomposition with 2 atoms. (a) (b) the spatial potential distributions of the
two atoms. (c) The frequency content of the atoms. (d) The time course of the
atoms. First atom drawn in solid line correspond with (a). Dash-dotted line
correspond with (b). First atom is seizure atom.
Figure 4
The seizure atom from Figure 3 is reconstructed in EEG coordinates after canonical
decomposition.
Dipole estimation then determines the dipole's
coordinates and orientation that best generate the given potential
distribution in a least-squares sense. For computational simplicity, we used a
spherical head model in this study.
2.2. Simulation
Consider a matrix of dimension
500-by-21 representing a 21-channel EEG section of 2.0 seconds long. Each vector of contains the
time course of an EEG channel:
In this simulation study includes both
seizure activity, and superimposed noise. Both signals are described as follows.
2.2.1. Synthetic seizure activity
The EEG of the ictal activity was generated using a
fixed dipole in a three-shell spherical head model. The different time courses
generated by the dipole are described below. The amplification factors at each
electrode were computed by solving the forward problem for a dipole in a
three-shell spherical head model consisting of a brain, a skull, and a scalp
compartment [40]. Each compartment had a specific conductivity with a
ratio equal to 1:1/16:1 for the brain, skull, and scalp compartment, respectively
[41]. The brain and scalp conductivity was [42]. Radii of the outer boundary of the brain, skull, and
scalp region equal to, respectively, 8 cm, 8.5 cm and 9.2 cm were used. Anumber of 21
electrodes were used: Fp2, F8, T4, T6, O2, F4, C4, P4, Fz, Cz, Pz, Fp1, F7,
T3, T5, O1, F3, C3, and P3 placed according to the 10–20 system for
electrode placement [43] and additional electrodes T1 and T2 on the temporal
region. The time course of the scalp potentials was stored in a 500-by-21
dimensional matrix , representing 2 seconds of EEG with sample frequency
of 250 Hz.Unless otherwise stated, dipole coordinates (left ear to
right ear), (posterior to
anterior) and (up, through
the Cz electrode) were [−0.5 0 0.1] and the dipole orientations , and were [1 0 0].The following seizure characteristics were simulated:Seizure activity in patients with mesial temporal lobe epilepsy (MTLE) is typically
expressed by a 4 Hz sinusoidal waveform [44]. In a first simulation we estimated the dipole
localisation error when seizure activity was represented by a 4 Hz sinusoid at
different noise levels (see Figure 5(a)). We also investigated the influence of the specific
waveform and estimated the localisation error when seizure activity was
represented by a 4 Hz sawtooth, instead of a sinusoidal wave, at different
noise levels.
Figure 5
Simulated data. (a) The time course of the
scalp potentials reflecting the 4 Hz epileptiform activity on each electrode.
(b) The simulated data matrix for an SNR equal to 0.7.
Ictal EEG
activity can have a frequency in the delta, theta, alpha, or beta range. In a
second simulation, therefore, we estimated the influence of the frequency of
the seizure signal on ictal scalp EEG source localisation at a fixed noise
level. We were particularly interested if the possible overlap in frequency
content between faster ictal activity and seizure activity would bias the
decomposition and thus the dipole estimate.Epilepticseizure activity can rapidly change in frequency. Ictal EEG activity is often
characterized by low-voltage fast activity in the beta range which gradually
slows down to alpha or theta frequencies with increasing amplitude. The
canonical decomposition exploits frequency information during the decomposition.
In order to test possible shortcomings of the canonical decomposition of ictal
EEG, we wanted to estimate the accuracy when the model is violated. In a third
simulation, we assessed the dipole localisation error when the frequency
changed during the 2 seconds under investigation. This does not give a
trilinear signal after wavelet transformation. We simulated a chirp that
linearly changed in frequency from 8 Hz at the start to 4 Hz at the end of the
considered 2 seconds. The signal also doubled in amplitude.In our previous
study [24], two atoms were obtained after the decomposition of in vivo seizures and a distinction could
be made between a seizure and a nonseizure atom. An interesting question is
how well different dipoles generating similar ictal signals will be
distinguished from each other. Such activity can be measured in the case of
multifocal epilepsy. In a fourth simulation, we considered two rhythmical
sources firing at the same frequency separated from each other by about 1 cm:
the second dipole had coordinates [−0.4 0 0.1]. These dipoles generated similar
potential distributions at the scalp.In a fifth simulation, the influence of the dipole localisation was investigated. Deeper
sources generate a weaker signal captured by the electrodes and are possibly
less accurately separated from background EEG. We varied the -coordinate of
the dipole between 0 and 0.8. and were kept fixed
at −0.5 and 0, respectively.21-channel EEG
does not have an optimal spatial resolution due to the low spatial sampling. In
a last simulation, we investigated how much the dipole localisation error could
be improved by using dense array EEG [45]. We used 148 electrodes, uniformly distributed over
the realistic domain of the same spherical head model.
2.2.2. Noise
A 500-by-21 noise matrix contained 2
seconds of awake background EEG activity, recorded with the same electrode
configuration as in (A), from a normal subject. On this matrix , muscle artifacts were superimposed. These muscle
artifacts were separated from contaminated background activity using BSS-CCA [46]. For the last simulation with dense-array EEG, the
noise was Gaussian, because no background EEG was available with this high
number of electrodes.
2.2.3. The simulated signal
In the simulation study the noise matrix is superimposed
on the signal matrix containing the
epileptical activity:
with . The root mean-squared (RMS) value of the signal is
then equal to
with the number of time samples; and the RMS value of the noise is equal to
The signal-to-noise ratio (SNR) is then defined as follows:
Changing the parameter alters the
noise level of our simulated signal.
3. RESULTS
Figure 6(a) shows the dipole localisation error in function of
the SNR when one dipole was fitted on the potential distribution extracted with
Candecomp. At an SNR of 0.4, the localisation error became smaller than 1 cm and
at an SNR of 0.7, the error between the simulated and the fitted dipole was only
5 mm. At SNRs lower than 0.26, there was no atom that clearly corresponded to
the seizure activity as can be seen by the large localisation error. At higher
noise levels, one atom contained pure rhythmical activity as can be seen by
the sudden improvement in dipole localisation error. Figure 6(b) shows the dipolefit error when a sawtooth was used
to simulate ictal EEG. The error was slightly larger compared to the perfect
sinusoidal signal, but still in the same range.
Figure 6
(a) The dipole localisation error in function of the noise level when a sinus waveform was
used as epileptic signal. (b) Idem as (a) but a sharp wave was used as
epileptic signal.
Figure 7 shows the dipole localisation error for different
frequencies of the simulated epileptic signal at an SNR of 0.7 (see Figure 5(b)). From this figure, it can be seen that the accuracy
of the separation of ictal EEG and the dipole fit does not depend on the
frequency of the signal. At all frequencies, a dipole is fitted with an error
smaller than 1 cm. This means that even when the frequency content of ictal
activity overlaps with frequency content of muscle artifacts, a good separation
is obtained.
Figure 7
The dipole localisation error as a function of the seizure frequency.
Figure 8 shows the dipole localisation error in function of
the SNR when the simulated epileptic signal changed in frequency and amplitude
during the considered 2 seconds. The figure strongly resembles Figure 6(a). This means that, although the signal is not well
localised in frequency, the decomposition still reliably detects the correct
location. This does not mean that the seizure activity is fully separated into
one atom. When we looked at the frequency component of the epileptic atom, this
component had maximal values around 6 Hz, that is, the average of the start (8 Hz)
and end frequency (4 Hz), while the frequency component in
the first simulation peaked
around 4 Hz. When the epileptic atom is reconstructed (see Figure 9), the change in frequency is not captured and the
reconstruction is poor in the beginning and at the end. This is also reflected
by a lower Candecomp fit percentage. In the first simulation, the fit
percentage was about 75%, while in this simulation only 58% of the activity
could be modeled. However, the best trilinear approximation captures a good
localisation.
Figure 8
The dipole localisation error as a function of the noise level, when the seizure activity
is changed in frequency during the time interval under investigation.
Figure 9
(a) The simulated frequency-modulated signal used in Figure 8 (b) The reconstructed atom.
Figure 10 shows in (a) the simulated localisation of two close
dipoles and in (b) the estimated localisation with the proposed method at an
SNR of 0.7. The Corcondia [30] indicated that three atoms were the correct number of
atoms for this simulated EEG. Two of them corresponded to the 2 dipolar foci.
The localisation error was for both sources about 5 mm, which indicates that a
reliable separation and localisation was obtained.
Figure 10
(a) The original dipole localisation of two simulated dipoles.
(b) The dipole localisation when three atoms were estimated with Candecomp.
The dipole localisation error as a function of the
position of the dipole is shown in Figure 11.
Figure 11
The dipole localisation error as a function of the -coordinate of the dipole, in order
to assess the influence of the depth of the dipole location.
The last figure, Figure 12, shows the dipole estimation error when 148
electrodes are used to acquire the EEG. It can be seen that with a high spatial
sampling, the estimation accuracy became about 1 mm.
Figure 12
The dipole localisation error as a function of the noise level, when the EEG is recorded
with 148 electrodes.
4. DISCUSSION
In [24], we introduced an automatic, fast, and sensitive
method for visualizing the ictal onset zone. The method was based on the
multiway Candecomp of wavelet-transformed EEG in distinct “atoms.” After the
decomposition, one atom could be identified as the epileptical atom, and the
spatial component of this atom revealed the focus. The method was also
validated on a large number of in
vivo seizures, and was not influenced by the presence of strong artifacts.
However, in that study, the extracted localising information was limited to the
2D potential distribution of epileptic activity over the electrodes. In the
present study, we looked at the 3D localisation in a spherical head, and
investigated the localising accuracy of a dipolar source fitted to the
extracted potential distribution.It is known that an infinite number of internal
electrical currents correspond with exactly the same potential distribution on
the scalp. The discussion if dipolar sources are superior to distributed
sources is beyond the scope of this study. We chose the dipolar source because
it is most popular. It is known that the generator of ictal activity can be an
extended area, and that a dipole situated in a certain region should be
considered as the center of mass of a larger activated brain region [7]. In [25], source densities were computed after Candecomp.We present here the framework for seizure onset
localisation with Candecomp as preprocessing step for EEG source localisation.
In fact, we focussed in the paper on seizure activity. However, the method can
also be used to localise all origins of oscillatory activity. We have shown
that in a spherical head model with realistically simulated EEG, our algorithm
correctly localised the seizure-related atom with an accuracy of about 5 mm,
even at SNR ratios that are lower than one encounters during real ictal
recordings. SNRs below 1 mean that the signal contains more noise than signal
(see, e.g., Figure 5). Although the shape of seizure activity will not be
perfectly sinusoidal, we have shown that the exact shape of the seizure signal
did not really influence the localisation accuracy. In a second simulation, we
have shown that the localisation error does not depend on the frequency of the
epileptic signal, and that overlapping frequency content of signal and noise,
representing muscle artifacts, does not lower the reliability of the
decomposition. The third simulation investigated a more challenging, but maybe
more realistic situation in which the frequency of the seizure changed during
the considered time interval. The resulting atom could not fully capture the
exact frequency-varying signal, as indicated by a lower fit-percentage of
Candecomp and the reconstructed epileptic signal. However, the best trilinear
approximation still reliably localised the signal. We should emphasize that
Candecomp is an interesting decomposition method due to its uniqueness
properties. However, the trilinear decomposition in space-time-frequency components
really restricts the activity that can be fully captured. When the frequency
content changes in time at a fixed position, the exact signal will not be fully
separated. However, the best trilinear approximation will separate a
rhythmical signal at the correct location. A similar result is observed when a
moving dipole was simulated. Moving activity cannot be captured with a
trilinear model, but the best approximation will result in an
“average” localisation. The fourth simulation showed that the localisation
error is quite insensitive to dipole localisation. In [47], it was observed that dipoles closer located to the
scalp, are slightly better estimated due the higher SNR associated with higher
dipoles. However, in our simulation this effect is negligible. We investigated
also the situation in which two dipolar sources generating the same signal were
placed near each other. This simulates multifocal epilepsy. The Corcondia [30] indicated that three atoms were the correct number of
atoms for this simulated EEG. Two of them corresponded to the 2 dipolar
sources. This example illustrates the interesting uniqueness property of
Candecomp [30] for EEG source localisation. When matrix
decomposition techniques like SVD or independent component analysis (ICA) would
have been used to decompose the EEG, only 1 rhythmical source would be
extracted as the 2 simulated sources are not independent nor uncorrelated. It
would then not be obvious to determine the correct number of dipoles. In our
approach, Candecomp determines the optimal number of components and only 1
dipole will correspond to each atom. Tensor decomposition techniques offer
clearly advantages over matrix decomposition techniques as preprocessing
technique for EEG source localisation. The last simulation assessed the
accuracy when more electrodes are used. It is known that dipole localisation
based on 21 electrode measurements gives only an approximate indication of
source localisation. However, using 148 electrodes can reduce the dipole
estimation error to less than 1 mm at the same low SNR's. So we think it is
worth to record the EEG with denser spatial sampling.The current simulation study is the most reliable
validation of our method. In the future, we plan to validate our method on in vivo seizures with a gold standard.
This gold standard can be intracranial EEG, ictal SPECT, or the site of
epilepsy surgery in patients who were rendered seizure free. Comparing the
estimated dipole localisation to other data, like ictal SPECT or MR-visible
lesions, however, will be biased by the accuracy of the onset delineation with
these diagnostic tools. We anticipate that the higher sensitivity and objectivity
of our Candecomp method as compared with visual assessment of the ictal EEG's
will improve and streamline the noninvasive presurgical evaluation of patients
with refractory partial epilepsy.
Authors: Wim De Clercq; Anneleen Vergult; Bart Vanrumste; Wim Van Paesschen; Sabine Van Huffel Journal: IEEE Trans Biomed Eng Date: 2006-12 Impact factor: 4.538
Authors: M De Vos; A Vergult; L De Lathauwer; W De Clercq; S Van Huffel; P Dupont; A Palmini; W Van Paesschen Journal: Neuroimage Date: 2007-05-21 Impact factor: 6.556
Authors: M R Nuwer; G Comi; R Emerson; A Fuglsang-Frederiksen; J M Guérit; H Hinrichs; A Ikeda; F J Luccas; P Rappelsburger Journal: Electroencephalogr Clin Neurophysiol Date: 1998-03
Authors: B N Cuffin; D Cohen; K Yunokuchi; R Maniewski; C Purcell; G R Cosgrove; J Ives; J Kennedy; D Schomer Journal: Ann Neurol Date: 1991-02 Impact factor: 10.422
Authors: Elena Urrestarazu; Jorge Iriarte; Manuel Alegre; Miguel Valencia; César Viteri; Julio Artieda Journal: Epilepsia Date: 2004-09 Impact factor: 5.864
Authors: Arno Onken; Jian K Liu; P P Chamanthi R Karunasekara; Ioannis Delis; Tim Gollisch; Stefano Panzeri Journal: PLoS Comput Biol Date: 2016-11-04 Impact factor: 4.475