Literature DB >> 18299949

Late hardware-induced sciatic nerve lesions after acetabular revision.

Martti Vastamäki1, Pekka Ylinen, Asko Puusa, Timo Paavilainen.   

Abstract

UNLABELLED: We encountered late hardware-induced sciatic nerve lesions after acetabular revision in six patients. There were five female patients and one male patient. The mean age of the patients at the time of index acetabular revision was 59.3 years (range, 42-76 years). The interval from the index acetabular revision to the onset of sciatic nerve symptoms averaged 9.4 months (range, 4-16 months) and that from the onset of symptoms to nerve release was 11.3 months (range, 8-13 months), except in two patients with intermittent symptoms in which it was 9 and 10.5 years, respectively. Sciatic nerve release was successful in two patients, but in four patients, the nerve had been partly or entirely cut by the metallic hardware resulting in a permanent deficit. The minimum followup was 2 years (mean, 4 years; range, 2-7 years). Mechanical irritation should be suspected in the case of any late sign of peroneal neuropathy after acetabular revision with a macrocup or antiprotrusion device, and plate fixation of the posterior column. We recommend exploration and nerve release before a permanent lesion of the nerve has developed. LEVEL OF EVIDENCE: Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2008        PMID: 18299949      PMCID: PMC2311475          DOI: 10.1007/s11999-008-0176-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  Sciatic neuropathy secondary to total hip arthroplasty wear debris.

Authors:  S R Fischer; D J Christ; B A Roehr
Journal:  J Arthroplasty       Date:  1999-09       Impact factor: 4.757

2.  Delayed sciatic nerve palsy following total hip arthroplasty.

Authors:  B Cohen; M Bhamra; B D Ferris
Journal:  Br J Clin Pract       Date:  1991

3.  Peripheral neuropathies associated with total hip arthroplasty.

Authors:  E R Weber; J R Daube; M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1976-01       Impact factor: 5.284

4.  Nerve injury in total hip arthroplasty.

Authors:  N A Johanson; P M Pellicci; P Tsairis; E A Salvati
Journal:  Clin Orthop Relat Res       Date:  1983-10       Impact factor: 4.176

5.  Delayed sciatic palsy after total hip replacement: case report.

Authors:  M S Edwards; N M Barbaro; S W Asher; W R Murray
Journal:  Neurosurgery       Date:  1981-07       Impact factor: 4.654

6.  Sciatic paralysis. A complication of bleeding following hip surgery.

Authors:  R E Fleming; C B Michelsen; F E Stinchfield
Journal:  J Bone Joint Surg Am       Date:  1979-01       Impact factor: 5.284

7.  Nerve palsy associated with total hip replacement. Risk factors and prognosis.

Authors:  T P Schmalzried; H C Amstutz; F J Dorey
Journal:  J Bone Joint Surg Am       Date:  1991-08       Impact factor: 5.284

8.  Sciatic neuropathy secondary to migration of trochanteric wire following total hip arthroplasty.

Authors:  S E Asnis; S Hanley; P D Shelton
Journal:  Clin Orthop Relat Res       Date:  1985-06       Impact factor: 4.176

9.  [Delayed neuropathy of the sciatic nerve after total hip replacement with an acetabular reinforcement ring].

Authors:  A Schuh; F Riedel; B Craiovan; G Zeiler
Journal:  Zentralbl Chir       Date:  2003-10       Impact factor: 0.942

10.  Total hip replacement and sciatic nerve trauma.

Authors:  M McLean
Journal:  Orthopedics       Date:  1986-08       Impact factor: 1.390

View more
  3 in total

1.  Section of the sciatic nerve by a metal acetabulum reinforcement ring: a literature review through one case.

Authors:  S Ruatti; M Grimaldi; D Saragaglia
Journal:  Eur J Orthop Surg Traumatol       Date:  2011-10-04

2.  Operative Management of Sciatic Nerve Palsy due to Impingement on the Metal Cage after Total Hip Revision: Case Report.

Authors:  Alessandro Bistolfi; Giuseppe Massazza; Davide Deledda; Elisa Lioce; Maurizio Crova
Journal:  Case Rep Med       Date:  2011-07-11

3.  Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

Authors:  Sun-Jung Yoon; Myung-Sik Park; Dean K Matsuda; Yun Ho Choi
Journal:  BMC Musculoskelet Disord       Date:  2018-06-04       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.