Technical report: Reliability and validity of the iSAM 9000 isokinetic dynamometer.

Julia C Orri1, Gibson F Darden.   

Abstract

This study assessed the mechanical reliability and validity of the INRTEK iSAM 9000 isokinetic dynamometer, and compared the obtained torque values of the prototype device with those from a traditional device. Sixty volunteers (40 men and 20 women) were tested at 60 degrees per second for shoulder, knee, and trunk flexion, and extension on both the Cybex 6000 and a new isokinetic dynamometer (iSAM 9000). Intraclass correlation coefficients (ICC) and standard errors of measurement (SEM) revealed a high level of reproducibility and precision in the device's torque measurements (ICC range = 0.94-0.98; SEM range = 5.2-29.7). Pearson r values revealed very high relationships between the two instruments (set 1: r = 0.84-0.93; set 2: r = 0.87-0.93; P < 0.05). Significantly higher peak torque for both sets of left and right knee flexion and extension, right shoulder extension and trunk extension was found for the iSAM 9000 compared to the Cybex 6000 (P < 0.05). The strong ICCs and small SEMs support the device's mechanical reliability and validity. The high correlation coefficients between the prototype dynamometer and the Cybex 6000 support the new device's validity in the measurement of isokinetic torque. The findings of this study will be used to refine the next generation of the INRTEK isokinetic device with respect to test protocols and the reliability of measuring human muscle performance.

Entities:  

Mesh:

Year:  2008        PMID: 18296991     DOI: 10.1519/JSC.0b013e31815fa2c8

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  4 in total

1.  Leg Dominance Effect on Isokinetic Muscle Strength of Hip Joint.

Authors:  Azza M Abdelmohsen
Journal:  J Chiropr Med       Date:  2019-05-07

2.  Evaluating injury risk in first and second league professional Portuguese soccer: muscular strength and asymmetry.

Authors:  Alberto Carvalho; Scott Brown; Eduardo Abade
Journal:  J Hum Kinet       Date:  2016-07-02       Impact factor: 2.193

3.  Intrarater reliability of the Humac NORM isokinetic dynamometer for strength measurements of the knee and shoulder muscles.

Authors:  Bas Habets; J Bart Staal; Marsha Tijssen; Robert van Cingel
Journal:  BMC Res Notes       Date:  2018-01-10

4.  Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer.

Authors:  Alberto César Pereira de Carvalho Froufe Andrade; Paolo Caserotti; Carlos Manuel Pereira de Carvalho; Eduardo André de Azevedo Abade; António Jaime da Eira Sampaio
Journal:  J Hum Kinet       Date:  2013-07-05       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.