Literature DB >> 18296541

Cyclic loading of rotator cuff reconstructions: single-row repair with modified suture configurations versus double-row repair.

Olaf Lorbach1, Felix Bachelier, Jochen Vees, Dieter Kohn, Dietrich Pape.   

Abstract

BACKGROUND: Double-row repair is suggested to have superior biomechanical properties in rotator cuff reconstruction compared with single-row repair. However, double-row rotator cuff repair is frequently compared with simple suture repair and not with modified suture configurations. HYPOTHESIS: Single-row rotator cuff repairs with modified suture configurations have similar failure loads and gap formations as double-row reconstructions. STUDY
DESIGN: Controlled laboratory study.
METHODS: We created 1 x 2-cm defects in 48 porcine infraspinatus tendons. Reconstructions were then performed with 4 single-row repairs and 2 double-row repairs. The single-row repairs included transosseous simple sutures; double-loaded corkscrew anchors in either a double mattress or modified Mason-Allen suture repair; and the Magnum Knotless Fixation Implant with an inclined mattress. Double-row repairs were either with Bio-Corkscrew FT using modified Mason-Allen stitches or a combination of Bio-Corkscrew FT and PushLock anchors using the SutureBridge Technique. During cyclic load (10 N to 60-200 N), gap formation was measured, and finally, ultimate load to failure and type of failure were recorded.
RESULTS: Double-row double-corkscrew anchor fixation had the highest ultimate tensile strength (398 +/- 98 N) compared to simple sutures (105 +/- 21 N; P < .0001), single-row corkscrews using a modified Mason-Allen stitch (256 +/- 73 N; P = .003) or double mattress repair (290 +/- 56 N; P = .043), the Magnum Implant (163 +/- 13 N; P < .0001), and double-row repair with PushLock and Bio-Corkscrew FT anchors (163 +/- 59 N; P < .0001). Single-row double mattress repair was superior to transosseous sutures (P < .0001), the Magnum Implant (P = .009), and double-row repair with PushLock and Bio-Corkscrew FT anchors (P = .009). Lowest gap formation was found for double-row double-corkscrew repair (3.1 +/- 0.1 mm) compared to simple sutures (8.7 +/- 0.2 mm; P < .0001), the Magnum Implant (6.2 +/- 2.2 mm; P = .002), double-row repair with PushLock and Bio-Corkscrew FT anchors (5.9 +/- 0.9 mm; P = .008), and corkscrews with modified Mason-Allen sutures (6.4 +/- 1.3 mm; P = .001).
CONCLUSION: Double-row double-corkscrew anchor rotator cuff repair offered the highest failure load and smallest gap formation and provided the most secure fixation of all tested configurations. Double-loaded suture anchors using modified suture configurations achieved superior results in failure load and gap formation compared to simple suture repair and showed similar loads and gap formation with double-row repair using PushLock and Bio-Corkscrew FT anchors. CLINICAL RELEVANCE: Single-row repair with modified suture configurations may lead to results comparable to several double-row fixations. If double-row repair is used, modified stitches might further minimize gap formation and increase failure load.

Entities:  

Mesh:

Year:  2008        PMID: 18296541     DOI: 10.1177/0363546508314424

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  31 in total

Review 1.  Rotator cuff: biology and current arthroscopic techniques.

Authors:  Olaf Lorbach; Marc Tompkins
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-21       Impact factor: 4.342

2.  Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

Authors:  O Lorbach; D Pape; F Raber; L C Busch; D Kohn; M Kieb
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11       Impact factor: 4.342

Review 3.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

4.  Tendon-grasping strength of various suture configurations for rotator cuff repair.

Authors:  Onur Hapa; F Alan Barber; Emin Sünbüloğlu; Yavuz Kocabey; Nazlı Sarkalkan; Gökhan Baysal
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-11-18       Impact factor: 4.342

5.  Reconstruction of 25 and 50 % subscapularis tears: a single anchor with a double-mattress suture is sufficient for the reconstruction.

Authors:  Olaf Lorbach; Christian Trennheuser; Matthias Kieb; Turgay Efe; Dieter Kohn; Konstantinos Anagnostakos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-30       Impact factor: 4.342

Review 6.  [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

Authors:  M H Baums; T Kostuj; H-M Klinger; R Papalia
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

7.  Coracoclavicular ligament reconstruction: biomechanical comparison of tendon graft repairs to a synthetic double bundle augmentation.

Authors:  Mathias Wellmann; Jan P Kempka; Steffen Schanz; Thore Zantop; Hazibullah Waizy; Michael J Raschke; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-02-19       Impact factor: 4.342

Review 8.  [Complications related to implants in arthroscopic shoulder surgery].

Authors:  O Lorbach; P Wilmes; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

9.  Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

Authors:  Mathias Wellmann; Philipp Wiebringhaus; Ina Lodde; Hazibullah Waizy; Christoph Becher; Michael J Raschke; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-08-20       Impact factor: 4.342

10.  Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques.

Authors:  Mustafa Citak; Manuel Backhaus; Dominik Seybold; Eduardo M Suero; Thomas A Schildhauer; Bernd Roetman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-29       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.