Literature DB >> 18290334

Cerebral tissue oxygen saturation calculated using low frequency haemoglobin oscillations measured by near infrared spectroscopy in adult ventilated patients.

Terence S Leung1, Martin M Tisdall, Ilias Tachtsidis, Martin Smith, David T Delpy, Clare E Elwell.   

Abstract

Oxy- (HbO2) and deoxy- (HHb) haemoglobin signals measured by near infrared (NIR) spectroscopy over the human frontal lobes frequently contain respiratory and low frequency oscillations (LFOs). It has been suggested previously that venous oxygen saturation (SvO2) can be calculated from these respiratory oscillations. In this paper, we investigated the use of a Fourier transform based algorithm to calculate an oxygen saturation measure known as S(osc)O2 which may be a close estimate of the underlying SvO2. S(osc)O2 was calculated using three different frequency ranges, (1) respiratory oscillations only, (2) LFOs only, and (3) both respiratory oscillations and LFOs. At each frequency range S(osc)O2 was calculated using either (1) the modified Beer-Lambert law (MBL) or (2) spatially resolved spectroscopy (SRS). In total six different measurements of S(osc)O2 were investigated here. Experiments were performed in six adult ventilated patients with traumatic brain injury. The patients' inspired oxygen fraction (FiO2) was raised in two hyperoxic phases. The calculated S(osc)O2 values were compared with other cerebral oxygenation measures including an intraparenchymal catheter based brain tissue oxygen tension (PbrO2) and the NIR based tissue oxygenation index (TOI). It was found that the S(osc)O2 calculated using the combined respiratory and LFO frequency range and the SRS method resulted in the highest detection rates of hyperoxic changes. This measure of S(osc)O2 may provide a viable, continuous, non invasive, bedside measure of cerebral venous oxygen saturation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18290334     DOI: 10.1007/978-0-387-74911-2_27

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   2.622


  5 in total

Review 1.  Implicit and explicit prior information in near-infrared spectral imaging: accuracy, quantification and diagnostic value.

Authors:  Brian W Pogue; Scott C Davis; Frederic Leblond; Michael A Mastanduno; Hamid Dehghani; Keith D Paulsen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

2.  Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

Authors:  Jana M Kainerstorfer; Angelo Sassaroli; Sergio Fantini
Journal:  J Biomed Opt       Date:  2016-10       Impact factor: 3.170

3.  Age-related changes in spontaneous oscillations assessed by wavelet transform of cerebral oxygenation and arterial blood pressure signals.

Authors:  Zengyong Li; Ming Zhang; Qing Xin; Site Luo; Ruofei Cui; Weiei Zhou; Liqian Lu
Journal:  J Cereb Blood Flow Metab       Date:  2013-01-30       Impact factor: 6.200

4.  Noninvasive optical quantification of cerebral venous oxygen saturation in humans.

Authors:  Jennifer M Lynch; Erin M Buckley; Peter J Schwab; David R Busch; Brian D Hanna; Mary E Putt; Daniel J Licht; Arjun G Yodh
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 5.482

5.  Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study.

Authors:  Asher A Mendelson; Ajay Rajaram; Daniel Bainbridge; Keith St Lawrence; Tracey Bentall; Michael Sharpe; Mamadou Diop; Christopher G Ellis
Journal:  J Clin Monit Comput       Date:  2020-10-26       Impact factor: 1.977