Literature DB >> 18276252

Nonlinear wavelet image processing: variational problems, compression, and noise removal through wavelet shrinkage.

A Charnbolle1, R A DeVore, N Y Lee, B J Lucier.   

Abstract

This paper examines the relationship between wavelet-based image processing algorithms and variational problems. Algorithms are derived as exact or approximate minimizers of variational problems; in particular, we show that wavelet shrinkage can be considered the exact minimizer of the following problem. Given an image F defined on a square I, minimize over all g in the Besov space B(1)(1)(L (1)(I)) the functional |F-g|(L2)(I)(2)+lambda|g|(B(1)(1 )(L(1(I)))). We use the theory of nonlinear wavelet image compression in L(2)(I) to derive accurate error bounds for noise removal through wavelet shrinkage applied to images corrupted with i.i.d., mean zero, Gaussian noise. A new signal-to-noise ratio (SNR), which we claim more accurately reflects the visual perception of noise in images, arises in this derivation. We present extensive computations that support the hypothesis that near-optimal shrinkage parameters can be derived if one knows (or can estimate) only two parameters about an image F: the largest alpha for which FinEpsilon(q)(alpha )(L(q)(I)),1/q=alpha/2+1/2, and the norm |F|B(q)(alpha)(L(q)(I)). Both theoretical and experimental results indicate that our choice of shrinkage parameters yields uniformly better results than Donoho and Johnstone's VisuShrink procedure; an example suggests, however, that Donoho and Johnstone's SureShrink method, which uses a different shrinkage parameter for each dyadic level, achieves a lower error than our procedure.

Year:  1998        PMID: 18276252     DOI: 10.1109/83.661182

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  13 in total

1.  Wavelet-encoding gradient-echo imaging sequence using real-time de-noising method for acquisition time reduction.

Authors:  Hacene Serrai; Richard Young
Journal:  MAGMA       Date:  2010-07-15       Impact factor: 2.310

2.  Parallel MR image reconstruction using augmented Lagrangian methods.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2010-11-18       Impact factor: 10.048

3.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

4.  High-resolution variable-density 3D cones coronary MRA.

Authors:  Nii Okai Addy; R Reeve Ingle; Holden H Wu; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2015-07-14       Impact factor: 4.668

5.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

6.  An Efficient Augmented Lagrangian Method for Statistical X-Ray CT Image Reconstruction.

Authors:  Jiaojiao Li; Shanzhou Niu; Jing Huang; Zhaoying Bian; Qianjin Feng; Gaohang Yu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

7.  Denoising and 4D visualization of OCT images.

Authors:  Madhusudhana Gargesha; Michael W Jenkins; Andrew M Rollins; David L Wilson
Journal:  Opt Express       Date:  2008-08-04       Impact factor: 3.894

8.  An efficient image compressor for charge coupled devices camera.

Authors:  Jin Li; Fei Xing; Zheng You
Journal:  ScientificWorldJournal       Date:  2014-07-07

9.  MR Image Reconstruction Using Block Matching and Adaptive Kernel Methods.

Authors:  Johannes F M Schmidt; Claudio Santelli; Sebastian Kozerke
Journal:  PLoS One       Date:  2016-04-26       Impact factor: 3.240

10.  A machine vision system for automated non-invasive assessment of cell viability via dark field microscopy, wavelet feature selection and classification.

Authors:  Ning Wei; Erwin Flaschel; Karl Friehs; Tim Wilhelm Nattkemper
Journal:  BMC Bioinformatics       Date:  2008-10-21       Impact factor: 3.169

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.