Literature DB >> 18270061

Anisotropic field-of-views in radial imaging.

P Z Larson1, P T Gurney, D G Nishimura.   

Abstract

Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T(2) imaging. They are robust to flow and motion, have diffuse aliasing patterns, and support short readouts and echo times. One drawback is that standard implementations do not support anisotropic field-of-view (FOV) shapes, which are used to match the imaging parameters to the object or region-of-interest. A set of fast, simple algorithms for 2-D and 3-D PR, and 3-D cones acquisitions are introduced that match the sampling density in frequency space to the desired FOV shape. Tailoring the acquisitions allows for reduction of aliasing artifacts in undersampled applications or scan time reductions without introducing aliasing in fully-sampled applications. It also makes possible new radial imaging applications that were previously unsuitable, such as imaging elongated regions or thin slabs. 2-D PR longitudinal leg images and thin-slab, single breath-hold 3-D PR abdomen images, both with isotropic resolution, demonstrate these new possibilities. No scan time to volume efficiency is lost by using anisotropic FOVs. The acquisition trajectories can be computed on a scan by scan basis.

Entities:  

Mesh:

Year:  2008        PMID: 18270061     DOI: 10.1109/TMI.2007.902799

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  28 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

Review 2.  Measurement techniques for magnetic resonance imaging of fast relaxing nuclei.

Authors:  Simon Konstandin; Armin M Nagel
Journal:  MAGMA       Date:  2013-07-24       Impact factor: 2.310

3.  High-resolution variable-density 3D cones coronary MRA.

Authors:  Nii Okai Addy; R Reeve Ingle; Holden H Wu; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2015-07-14       Impact factor: 4.668

4.  Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences.

Authors:  Jun Chen; Michael Carl; Yajun Ma; Hongda Shao; Xing Lu; Bimin Chen; Eric Y Chang; Zhihong Wu; Jiang Du
Journal:  NMR Biomed       Date:  2016-08-05       Impact factor: 4.044

5.  A novel method for quantitative monitoring of transplanted islets of langerhans by positive contrast magnetic resonance imaging.

Authors:  L A Crowe; F Ris; S Nielles-Vallespin; P Speier; S Masson; M Armanet; P Morel; C Toso; D Bosco; T Berney; J-P Vallee
Journal:  Am J Transplant       Date:  2011-05-12       Impact factor: 8.086

6.  Depiction of achilles tendon microstructure in vivo using high-resolution 3-dimensional ultrashort echo-time magnetic resonance imaging at 7 T.

Authors:  Misung Han; Peder E Z Larson; Jing Liu; Roland Krug
Journal:  Invest Radiol       Date:  2014-05       Impact factor: 6.016

7.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

8.  Quantifying temperature-dependent T1 changes in cortical bone using ultrashort echo-time MRI.

Authors:  Misung Han; Viola Rieke; Serena J Scott; Eugene Ozhinsky; Vasant A Salgaonkar; Peter D Jones; Peder E Z Larson; Chris J Diederich; Roland Krug
Journal:  Magn Reson Med       Date:  2015-09-21       Impact factor: 4.668

9.  Anisotropic field-of-view shapes for improved PROPELLER imaging.

Authors:  Peder E Z Larson; Michael S Lustig; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2008-09-24       Impact factor: 2.546

10.  Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

Authors:  Thomas Benkert; Li Feng; Daniel K Sodickson; Hersh Chandarana; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2016-09-09       Impact factor: 4.668

View more