BACKGROUND: Measurements of free thyroxine (FT4) and free triiodothyronine (FT3) are important for the diagnosis and monitoring of thyroid diseases. Considerable differences among methods limit their clinical utility, however, and accurate methods are needed for various clinical specimens. We describe a direct equilibrium dialysis (ED)-liquid chromatography (LC)/tandem mass spectrometry (MS/MS) method for FT4 and FT3. METHODS: ED was selected as the separation step. Serum samples were dialyzed 1:1 against a simple protein-free buffer for 20 h at 37 degrees C. Thyroid hormones in dialysates were purified by online solid-phase extraction (SPE), then chromatographically separated and quantified in positive ion and multiple reaction monitoring modes. RESULTS: For FT4 and FT3, the lower and upper limits of quantification were 1 ng/L (pg/mL) and 400 ng/L with total imprecision <10%. The method correlated well with an ED-RIA, 2 direct immunoassay methods for FT4, and 1 direct immunoassay and 1 tracer dialysis method for FT3. The adult reference intervals were 12.8-22.2 ng/L for FT4 and 3.62-6.75 ng/L for FT3. Reference intervals for the second trimester of pregnancy (14-20 weeks of gestation) were also established. CONCLUSIONS: We developed a simple protein-free buffer and ED procedure. The performance characteristics and high throughput of the LC-MS/MS method with online SPE for FT4 and FT3 (also reverse T3) are sufficient for the intended clinical use.
BACKGROUND: Measurements of free thyroxine (FT4) and free triiodothyronine (FT3) are important for the diagnosis and monitoring of thyroid diseases. Considerable differences among methods limit their clinical utility, however, and accurate methods are needed for various clinical specimens. We describe a direct equilibrium dialysis (ED)-liquid chromatography (LC)/tandem mass spectrometry (MS/MS) method for FT4 and FT3. METHODS: ED was selected as the separation step. Serum samples were dialyzed 1:1 against a simple protein-free buffer for 20 h at 37 degrees C. Thyroid hormones in dialysates were purified by online solid-phase extraction (SPE), then chromatographically separated and quantified in positive ion and multiple reaction monitoring modes. RESULTS: For FT4 and FT3, the lower and upper limits of quantification were 1 ng/L (pg/mL) and 400 ng/L with total imprecision <10%. The method correlated well with an ED-RIA, 2 direct immunoassay methods for FT4, and 1 direct immunoassay and 1 tracer dialysis method for FT3. The adult reference intervals were 12.8-22.2 ng/L for FT4 and 3.62-6.75 ng/L for FT3. Reference intervals for the second trimester of pregnancy (14-20 weeks of gestation) were also established. CONCLUSIONS: We developed a simple protein-free buffer and ED procedure. The performance characteristics and high throughput of the LC-MS/MS method with online SPE for FT4 and FT3 (also reverse T3) are sufficient for the intended clinical use.
Authors: Stephen E Long; Brittany L Catron; Ashley Sp Boggs; Susan Sc Tai; Stephen A Wise Journal: Am J Clin Nutr Date: 2016-08-17 Impact factor: 7.045
Authors: Andrea E DeBarber; Travis Geraci; Vincent P Colasurdo; Sarah A Hackenmueller; Thomas S Scanlan Journal: J Chromatogr A Date: 2008-09-12 Impact factor: 4.759
Authors: Peter N Taylor; Rebecca Richmond; Neil Davies; Adrian Sayers; Kirsty Stevenson; Wolfram Woltersdorf; Andrew Taylor; Alix Groom; Kate Northstone; Susan Ring; Onyebuchi Okosieme; Aled Rees; Dorothea Nitsch; Graham R Williams; George Davey Smith; John W Gregory; Nicholas J Timpson; Jonathan H Tobias; Colin M Dayan Journal: J Clin Endocrinol Metab Date: 2015-11-23 Impact factor: 5.958