Literature DB >> 18257067

Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy.

Tobias Jarmar1, Anders Palmquist, Rickard Brånemark, Leif Hermansson, Håkan Engqvist, Peter Thomsen.   

Abstract

The surface properties of materials are believed to control most of the biological reactions toward implanted materials. To study the surface structure, elemental distribution, and morphology, using transmission electron microscopy (TEM) techniques, thin foils of the surface (in cross-section) are needed. These have been cumbersome to produce, in particular, from the normally irregular screw-shaped metal implants. Focused ion beam (FIB) microscopy has been developed partly for TEM sample preparation, mainly within the microelectronics industry. Our study describes a method based on FIB for producing electron transparent foils/sections from a metal implant for TEM analysis. Using a screw-shaped titanium dental implant, it was demonstrated that thin foils can be prepared with submicron specificity and from almost any surface geometry. A comparison of different lift-out techniques showed that the in situ lift-out preparation technique allowed plasma cleaning and produced particularly good samples with excellent yield. The titanium oxide on the implant surface was analyzed using energy-filtered TEM (EFTEM) and high-resolution TEM (HRTEM) and the TiO(2) rutile phase being determined via the lattice parameters. This study provides the first set of data for the optimization of a new route for preparation and analysis of biomaterial surfaces and interfaces. 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18257067     DOI: 10.1002/jbm.a.31856

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  13 in total

Review 1.  Titanium oral implants: surface characteristics, interface biology and clinical outcome.

Authors:  Anders Palmquist; Omar M Omar; Marco Esposito; Jukka Lausmaa; Peter Thomsen
Journal:  J R Soc Interface       Date:  2010-06-30       Impact factor: 4.118

Review 2.  Resolving the CaP-bone interface: a review of discoveries with light and electron microscopy.

Authors:  Kathryn Grandfield; Anders Palmquist; Håkan Engqvist; Peter Thomsen
Journal:  Biomatter       Date:  2012 Jan-Mar

3.  Bone-titanium oxide interface in humans revealed by transmission electron microscopy and electron tomography.

Authors:  Anders Palmquist; Kathryn Grandfield; Birgitta Norlindh; Torsten Mattsson; Rickard Brånemark; Peter Thomsen
Journal:  J R Soc Interface       Date:  2011-08-17       Impact factor: 4.118

4.  Free form fabricated features on CoCr implants with and without hydroxyapatite coating in vivo: a comparative study of bone contact and bone growth induction.

Authors:  Kathryn Grandfield; Anders Palmquist; Stéphane Gonçalves; Andy Taylor; Mark Taylor; Lena Emanuelsson; Peter Thomsen; Håkan Engqvist
Journal:  J Mater Sci Mater Med       Date:  2011-02-09       Impact factor: 3.896

5.  Ex vivo alendronate localization at the mesoporous titania implant/bone interface.

Authors:  Johan Karlsson; Necati Harmankaya; Stefan Allard; Anders Palmquist; Mats Halvarsson; Pentti Tengvall; Martin Andersson
Journal:  J Mater Sci Mater Med       Date:  2015-01-11       Impact factor: 3.896

6.  Nanoscale bonding between human bone and titanium surfaces: osseohybridization.

Authors:  Jun-Sik Kim; Seok-Man Kang; Kyung-Won Seo; Kyung-Yen Nahm; Kyu-Rhim Chung; Seong-Hun Kim; Jae-Pyeong Ahn
Journal:  Biomed Res Int       Date:  2015-01-15       Impact factor: 3.411

7.  Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems.

Authors:  Furqan A Shah; Martin L Johansson; Omar Omar; Hanna Simonsson; Anders Palmquist; Peter Thomsen
Journal:  PLoS One       Date:  2016-06-14       Impact factor: 3.240

8.  Direct communication between osteocytes and acid-etched titanium implants with a sub-micron topography.

Authors:  Furqan A Shah; Patrik Stenlund; Anna Martinelli; Peter Thomsen; Anders Palmquist
Journal:  J Mater Sci Mater Med       Date:  2016-10-03       Impact factor: 3.896

Review 9.  Bio-mimicking nano and micro-structured surface fabrication for antibacterial properties in medical implants.

Authors:  Alka Jaggessar; Hesam Shahali; Asha Mathew; Prasad K D V Yarlagadda
Journal:  J Nanobiotechnology       Date:  2017-10-02       Impact factor: 10.435

10.  The clinical, radiological, microbiological, and molecular profile of the skin-penetration site of transfemoral amputees treated with bone-anchored prostheses.

Authors:  Maria Lennerås; Georgios Tsikandylakis; Margarita Trobos; Omar Omar; Forugh Vazirisani; Anders Palmquist; Örjan Berlin; Rickard Brånemark; Peter Thomsen
Journal:  J Biomed Mater Res A       Date:  2016-11-07       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.