The use of ultrasound in acquisition of the anterior pelvic plane in computer-assisted total hip replacement: a cadaver study.

S Parratte1, P Kilian, V Pauly, P Champsaur, J-N A Argenson.   

Abstract

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2 degrees; p < 0.001 and 19.25 degrees with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2 degrees, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used.

Entities:  

Mesh:

Year:  2008        PMID: 18256101     DOI: 10.1302/0301-620X.90B2.19950

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position.

Authors:  Ernst Sendtner; Tibor Schuster; Michael Wörner; Thomas Kalteis; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2010-05-21       Impact factor: 3.075

2.  Intra- and intersurgeon variability in image-free navigation system for THA.

Authors:  Hirotsugu Ohashi; Masanori Matsuura; Yusaku Okamoto; Yoshiaki Okajima
Journal:  Clin Orthop Relat Res       Date:  2009-04-21       Impact factor: 4.176

3.  Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

Authors:  Jaeyeong Park; Jun-Young Kim; Hyun Deok Kim; Young Cheol Kim; Anna Seo; Minkyu Je; Jong Uk Mun; Bia Kim; Il Hyung Park; Shin-Yoon Kim
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

4.  Reply to the Letter to the Editor: Editor's Spotlight/Take 5: No Benefit after THA Performed with Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study.

Authors:  Sebastien Parratte; Matthieu Ollivier; Alexandre Lunebourg; Xavier Flecher; Jean-Noel A Argenson
Journal:  Clin Orthop Relat Res       Date:  2016-11-18       Impact factor: 4.176

5.  What do we get from navigation in primary THA?

Authors:  Lisa Renner; Viktor Janz; Carsten Perka; Georgi I Wassilew
Journal:  EFORT Open Rev       Date:  2017-03-13

6.  Electromagnetic navigation system for acetabular component placement in total hip arthroplasty is more precise and accurate than the freehand technique: a randomized, controlled trial with 84 patients.

Authors:  Rene Mihalič; Jurij Zdovc; Janez Mohar; Rihard Trebše
Journal:  Acta Orthop       Date:  2020-07-01       Impact factor: 3.717

7.  Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens.

Authors:  Arthur J Kievit; Johannes G G Dobbe; Wouter H Mallee; Leendert Blankevoort; Geert J Streekstra; Matthias U Schafroth
Journal:  Hip Int       Date:  2019-09-11       Impact factor: 2.135

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.