Literature DB >> 18254740

Rehabilitation of edentulous mandibles by means of five TiUnite implants after one-stage surgery: a 1-year retrospective study of 90 patients.

Bertil Friberg1, Torsten Jemt.   

Abstract

BACKGROUND: Recently, the present team reported the 1-year data of one-stage surgery and mainly early loading performed in edentulous mandibles using 750 turned Brånemark System implants in 152 patients.
PURPOSE: The aim of the present investigation was to retrospectively evaluate the 1-year results of the same treatment technique, using Brånemark System implants with an oxidized surface (TiUnite, Nobel Biocare AB, Göteborg, Sweden). The outcome was compared with that of the former study (control) on turned implants.
MATERIALS AND METHODS: The present study involved 90 individuals with 450 TiUnite implants of mainly the Brånemark System Mark III design, placed in edentulous mandibles and using one-stage surgery. The prosthetic procedure was commenced as a mean 8 days after the surgical intervention. Intraoral radiographs were obtained at prosthesis insertion and at the 1-year annual checkup. Failure rates of test and control groups were compared by means of the chi-square test.
RESULTS: No implants were found to be mobile up to and including the first annual checkup, resulting in an implant cumulative survival rate (CSR) of 100%. The corresponding CSR for the control group was 97.5%, and this difference in implant survival was statistically significant when analyzed with the chi-square test (p < .001). A statistically significant difference was also demonstrated (p < .01) when conducting the same statistical analysis on the patient level. The mean marginal bone resorption during the first year of function was 0.49 mm (SD 0.56), and the corresponding figures for the control study were 0.39 mm (SD 0.46). The central TiUnite implant, that is, the one placed in or in close relation to the symphyseal region showed significantly more bone loss (p < .05) than the corresponding central turned implant of the control study. Distally positioned test implants demonstrated less marginal bone loss than the corresponding central one.
CONCLUSIONS: The outcome of 450 TiUnite implants placed in 90 patients with edentulous mandibles, of which 380 implants in 76 patients were followed for 1 year, showed an implant CSR of 100%. The figure was significantly different from the control study result of 97.5% on turned surface implants. The levels of marginal bone were close to identical for test and control implants at the 1-year checkup.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18254740     DOI: 10.1111/j.1708-8208.2007.00060.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  9 in total

1.  Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

Authors:  L S Carneiro; H A da Cunha; C R Leles; E F Mendonça
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Analysis of the compatibility of dental implant systems in fibula free flap reconstruction.

Authors:  Ramin Carbiner; Waseem Jerjes; Kaveh Shakib; Peter V Giannoudis; Colin Hopper
Journal:  Head Neck Oncol       Date:  2012-06-21

3.  Anodisation Increases Integration of Unloaded Titanium Implants in Sheep Mandible.

Authors:  Warwick J Duncan; Min-Ho Lee; Tae-Sung Bae; Sook-Jeong Lee; Jennifer Gay; Carolina Loch
Journal:  Biomed Res Int       Date:  2015-09-08       Impact factor: 3.411

4.  Influence of Implant Neck Design on Crestal Bone Loss: A Comparative Study.

Authors:  Yojana B Patil; Swati Joshi Asopa; Aashana Goel; Divya Jyoti; Nagaveni S Somayaji; Robin Sabharwal
Journal:  Niger J Surg       Date:  2020-02-10

5.  Novel Implant Coating Agent Promotes Gene Expression of Osteogenic Markers in Rats during Early Osseointegration.

Authors:  Kostas Bougas; Ryo Jimbo; Ying Xue; Kamal Mustafa; Ann Wennerberg
Journal:  Int J Biomater       Date:  2012-10-30

6.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

7.  The influence of surface treatment on the implant roughness pattern.

Authors:  Marcio Borges Rosa; Tomas Albrektsson; Carlos Eduardo Francischone; Humberto Osvaldo Schwartz Filho; Ann Wennerberg
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

8.  Crestal bone loss around dental implants after implantation of Tricalcium phosphate and Platelet- Rich Plasma: A comparative study.

Authors:  Sravani Uppala; Anuj Singh Parihar; Varsha Modipalle; Litto Manual; Vinni Mary Oommen; Pallavi Karadiguddi; Parkhi Gupta
Journal:  J Family Med Prim Care       Date:  2020-01-28

Review 9.  Etiology, occurrence, and consequences of implant loss.

Authors:  Cristiano Tomasi; Jan Derks
Journal:  Periodontol 2000       Date:  2022-02       Impact factor: 12.239

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.