Literature DB >> 18250202

Level of patient and operator dose in the largest cardiac centre in Greece.

V Tsapaki1, S Patsilinakos, V Voudris, A Magginas, S Pavlidis, T Maounis, G Theodorakis, M Koutelou, T Vrantza, M Nearchou, N Nikolaki, N Kollaros, E Kyrozi, S Kottou, P Karaiskos, E Neofotistou, D Cokkinos.   

Abstract

The objective of this study was to investigate the patient and staff doses in the most frequent interventional cardiology (IC) procedures performed in Onassio, the largest Cardiac Centre in Greece. Data were collected from three digital X-ray systems for 212 coronary angiographies, 203 percutaneous transluminal coronary angioplasties (PTCA) and 134 various electrophysiological studies. Patient skin dose was measured using suitably calibrated slow radiotherapy films and cardiologist dose using suitably calibrated thermoluminescent dosemeters placed on left arm, hand and foot. Patient median dose area product (DAP) (all examinations) ranged between 6.7 and 83.5 Gy cm2. Patient median skin dose in PTCA was 799 mGy (320-1660 mGy) and in RF ablation 160 mGy (35-1920 mGy). Median arm, hand and foot dose to the cardiologist were 12.6, 27 and 13 microSv, respectively, per procedure. The great range of radiation doses received by both patients and operators confirms the need for continuous monitoring of all IC techniques.

Entities:  

Mesh:

Year:  2008        PMID: 18250202     DOI: 10.1093/rpd/ncn006

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 2.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

3.  The importance of protection glasses during neuroangiographies: A study on radiation exposure at the lens of the primary operator.

Authors:  J B Tavares; E Sacadura-Leite; T Matoso; L L Neto; L Biscoito; J Campos; A Sousa-Uva
Journal:  Interv Neuroradiol       Date:  2016-02-02       Impact factor: 1.610

4.  Impact of Allura Clarity Technology on Radiation Dose Exposure During Left Atrial Appendage Closure.

Authors:  Emilia Studzińska; Maria Anna Staniszewska
Journal:  Pol J Radiol       Date:  2017-10-20

5.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.