Synthetic aperture techniques with a virtual source element.

C H Frazier1, W R O'Brien.   

Abstract

A new imaging technique has been proposed that combines conventional B-mode and synthetic aperture imaging techniques to overcome the limited depth of field for a highly focused transducer. The new technique improves lateral resolution beyond the focus of the transducer by considering the focus a virtual element and applying synthetic aperture focusing techniques. In this paper, the use of the focus as a virtual element is examined, considering the issues that are of concern when imaging with an array of actual elements: the tradeoff between lateral resolution and sidelobe level, the tradeoff between system complexity (channel count/amount of computation) and the appearance of grating lobes, and the issue of signal to noise ratio (SNR) of the processed image. To examine these issues, pulse-echo RF signals were collected for a tungsten wire in degassed water, monofilament nylon wires in a tissue-mimicking phantom, and cyst targets in the phantom. Results show apodization lowers the sidelobes, but only at the expense of lateral resolution, as is the case for classical synthetic aperture imaging. Grating lobes are not significant until spatial sampling is more than one wavelength, when the beam is not steered. Resolution comparable to the resolution at the transducer focus can be achieved beyond the focal region while obtaining an acceptable SNR. Specifically, for a 15-MHz focused transducer, the 6-dB beamwidth at the focus is 157 mum, and with synthetic aperture processing the 6-dB beamwidths at 3, 5, and 7 mm beyond the focus are 189 mum, 184 mum, and 215 mum, respectively. The image SNR is 38.6 dB when the wire is at the focus, and it is 32.8 dB, 35.3 dB, and 38.1 dB after synthetic aperture processing when the wire is 3, 5, and 7 mm beyond the focus, respectively. With these experiments, the virtual source has been shown to exhibit the same behavior as an actual transducer element in response to synthetic aperture processing techniques.

Entities:  

Year:  1998        PMID: 18244172     DOI: 10.1109/58.646925

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  27 in total

1.  Accurate ultrasound imaging based on range point migration method for the depiction of fetal surface.

Authors:  Hirofumi Taki; Shinya Tanimura; Takuya Sakamoto; Tsuyoshi Shiina; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2014-09-13       Impact factor: 1.314

2.  Imaging with unfocused regions of focused ultrasound beams.

Authors:  Roger Zemp; Michael F Insana
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

3.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  Effects of line fiducial parameters and beamforming on ultrasound calibration.

Authors:  Golafsoun Ameri; John S H Baxter; A Jonathan McLeod; Terry M Peters; Elvis C S Chen
Journal:  J Med Imaging (Bellingham)       Date:  2017-02-28

5.  Improving beamforming performance by phased synthetic aperture imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2016-10-28       Impact factor: 1.314

6.  Comparison of virtual source synthetic aperture beamforming with an element-based model.

Authors:  Nick Bottenus
Journal:  J Acoust Soc Am       Date:  2018-05       Impact factor: 1.840

7.  The Use of Acoustic Radiation Force Decorrelation-Weighted Pulse Inversion for Enhanced Ultrasound Contrast Imaging.

Authors:  Elizabeth B Herbst; Sunil Unnikrishnan; Shiying Wang; Alexander L Klibanov; John A Hossack; Frank William Mauldin
Journal:  Invest Radiol       Date:  2017-02       Impact factor: 6.016

8.  Synthetic-aperture based photoacoustic re-beamforming (SPARE) approach using beamformed ultrasound data.

Authors:  Haichong K Zhang; Muyinatu A Lediju Bell; Xiaoyu Guo; Hyun Jae Kang; Emad M Boctor
Journal:  Biomed Opt Express       Date:  2016-07-19       Impact factor: 3.732

9.  Effects of motion on correlations of pulse-echo ultrasound signals: Applications in delay estimation and aperture coherence.

Authors:  Dongwoon Hyun; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2020-03       Impact factor: 1.840

10.  High-resolution vascular tissue characterization in mice using 55MHz ultrasound hybrid imaging.

Authors:  Ahmed M Mahmoud; Cesar Sandoval; Bunyen Teng; Jurgen B Schnermann; Karen H Martin; S Jamal Mustafa; Osama M Mukdadi
Journal:  Ultrasonics       Date:  2012-11-16       Impact factor: 2.890

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.