Literature DB >> 18242445

Long-term follow-up of hyperopic laser in situ keratomileusis correction using the Star S2 excimer laser.

Rajen U Desai1, Atul Jain, Edward E Manche.   

Abstract

PURPOSE: To prospectively evaluate the safety, efficacy, predictability, and long-term stability of hyperopic laser in situ keratomileusis (LASIK) using the Star S2 excimer laser (Visx).
SETTING: Department of Ophthalmology, Stanford University School of Medicine, Stanford, California, USA.
METHODS: This study evaluated 41 eyes of 27 patients who had LASIK for the correction of spherical hyperopia. Patients were divided into 3 groups based on preoperative cycloplegic refraction: low hyperopia (less than +2.00 diopters [D]), medium hyperopia (+2.00 to +4.00 D), and high hyperopia (more than +4.00 D).
RESULTS: In all eyes, the mean preoperative spherical equivalent (SE) was +2.53 D (range +0.75 to +5.25 D) and the mean attempted SE was +2.58 D (range +0.75 to +5.25 D). At the last visit (mean 5.29 years), the mean SE was +0.44 D +/- 0.69 (SD) in the low hyperopia group, +0.58 +/- 0.56 D in the medium hyperopia group, and +0.59 +/- 1.18 D in the high hyperopia group. The percentage of eyes within +/-1.00 D of emmetropia was 82.4%, 75.0%, and 66.7%, respectively (68.9% overall). The uncorrected visual acuity was 20/40 or better in 100% of eyes in the low hyperopia group, 91.7% in the medium hyperopia group, and 66.7% in the high hyperopia group (87.8% overall). The hyperopic shift between 1 year and the last visit was +0.18 D, +0.30 D, and +0.55 D, respectively (+0.40 D overall; range -1.25 to +2.63 D).
CONCLUSIONS: Hyperopic LASIK using the Star S2 excimer laser was safe, effective, and predictable for hyperopia up to +4.10 D (mean of high group). A mild regression of the refractive effect was seen over the 5-year follow-up.

Entities:  

Mesh:

Year:  2008        PMID: 18242445     DOI: 10.1016/j.jcrs.2007.09.019

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Epithelial thickness after hyperopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2010-08       Impact factor: 3.573

2.  Long-Term Followup of Laser In Situ Keratomileusis for Hyperopia Using a 213 nm Wavelength Solid-State Laser.

Authors:  Carmina Franz G Quito; Archimedes Lee D Agahan; Raymond P Evangelista
Journal:  ISRN Ophthalmol       Date:  2013-03-03

3.  One-year eye-to-eye comparison of wavefront-guided versus wavefront-optimized laser in situ keratomileusis in hyperopes.

Authors:  Christopher S Sáles; Edward E Manche
Journal:  Clin Ophthalmol       Date:  2014-11-12

4.  Assessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction.

Authors:  Mohamed Tarek El-Naggar; Dikran Gilbert Hovaghimian
Journal:  Electron Physician       Date:  2017-03-25

5.  Lasik as a Solution for High Hypermetropia.

Authors:  Alma Biscevic; Ajla Pidro; Melisa Ahmedbegovic Pjano; Senad Grisevic; Nina Ziga; Maja Bohac
Journal:  Med Arch       Date:  2019-06

6.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.