Literature DB >> 18240052

CT-based planning of a single-radius femoral component in total knee arthroplasty using the ROBODOC system.

Takehito Hananouchi1, Nobuo Nakamura, Akihiro Kakimoto, Hideki Yohsikawa, Nobuhiko Sugano.   

Abstract

OBJECTIVE: The purpose of this study was to propose our CT-based planning approach for knee arthroplasty on the basis of the femoral flexion-extension (FE) axis, and to evaluate whether this approach was valid by comparing the results with those obtained using conventional anterior-referenced planning.
MATERIALS AND METHODS: Virtual implantation of a sagittal single-radius component was performed in 34 normal knees. The transepicondylar axis (TEA) was identified as the FE axis, and was modified in the coronal plane to intersect the femoral mechanical axis at a right angle, if necessary. The implant was then selected that had a radius closest to the distance between the modified TEA and the distal condyle end. The implant position and size were compared for the two plans.
RESULTS: In almost all cases, slight modification of the TEA was required. However, there was no significant change in the distance from the TEA to the posterior and distal condyles. In comparison to the results obtained with our planning approach, the conventional plan resulted in antero-superior deviation of the implant sagittal center to the FE axis and/or selection of a larger size of prosthesis.
CONCLUSION: Although the TEA must be modified slightly when referencing it as the FE axis, our planning approach may be valid for femoral single-radius components because the single axis of the component could be matched with the FE axis.

Entities:  

Mesh:

Year:  2008        PMID: 18240052     DOI: 10.3109/10929080701882580

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  5 in total

1.  The future of telesurgery: a universal system with haptic sensation.

Authors:  Michael Stark; Tahar Benhidjeb; Stefano Gidaro; Emilio Ruiz Morales
Journal:  J Turk Ger Gynecol Assoc       Date:  2012-03-01

2.  Alignment of the lower extremity mechanical axis by computer-aided design and application in total knee arthroplasty.

Authors:  Yuan Z Zhang; Sheng Lu; Hui Q Zhang; Zhong M Jin; Jian M Zhao; Jian Huang; Zhi F Zhang
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

3.  Sagittal gap balancing with the concept of a single radius femoral component in posterior cruciate sacrificing total knee arthroplasty with patient-specific instrumentation.

Authors:  Takehito Hananouchi
Journal:  Int Orthop       Date:  2014-10-02       Impact factor: 3.075

4.  Protocol for evaluation of robotic technology in orthopedic surgery.

Authors:  Milad Masjedi; Zahra Jaffry; Simon Harris; Justin Cobb
Journal:  Adv Orthop       Date:  2013-09-19

5.  Housing design and testing of a surgical robot developed for orthopaedic surgery.

Authors:  Lai-Yin Qin; Jing Zhou Wen; Chun-Sing Chui; Kwok-Sui Leung
Journal:  J Orthop Translat       Date:  2016-03-11       Impact factor: 5.191

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.