Literature DB >> 18238697

A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems.

M H Bae1, M K Jeong.   

Abstract

We propose an all point transmit and receive focusing method based on transmit synthetic focusing combined with receive dynamic focusing in a linear array transducer. In the method, on transmit, a virtual source element is assumed to be located at the transmit focal depth of conventional B-mode imaging systems, and transmit synthetic focusing is used in two half planes, one before and the other after the transmit focal depth, using the RF data of each scanline, together with all other relevant RF scanline data previously stored. The proposed new method uses the same data acquisition scheme as the conventional focusing method while maintaining the same frame rate via high-speed signal processing, but it is not suitable for imaging moving objects. It improves upon the lateral resolution and sidelobe level at all imaging depths. Also, it increases the transmit power and image signal-to-noise ratio (SNR), due to transmit field synthesis, and extends the image penetration depth as well. Evaluations with simulation and experimental data show much improvement in resolution and SNR at all imaging depths.

Year:  2000        PMID: 18238697     DOI: 10.1109/58.883540

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  17 in total

1.  Weighted Capon beamformer combined with coded excitation in ultrasound imaging.

Authors:  Seyed Amin Izadi; Ali Mahloojifar; Babak Mohammadzadeh Asl
Journal:  J Med Ultrason (2001)       Date:  2015-07-28       Impact factor: 1.314

2.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

3.  Extending Retrospective Encoding for Robust Recovery of the Multistatic Data Set.

Authors:  Rehman Ali; Carl D Herickhoff; Dongwoon Hyun; Jeremy J Dahl; Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-23       Impact factor: 2.725

4.  Angular coherence in ultrasound imaging: Theory and applications.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2017-03       Impact factor: 1.840

5.  Improving beamforming performance by phased synthetic aperture imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2016-10-28       Impact factor: 1.314

6.  Comparison of virtual source synthetic aperture beamforming with an element-based model.

Authors:  Nick Bottenus
Journal:  J Acoust Soc Am       Date:  2018-05       Impact factor: 1.840

7.  Effects of motion on correlations of pulse-echo ultrasound signals: Applications in delay estimation and aperture coherence.

Authors:  Dongwoon Hyun; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2020-03       Impact factor: 1.840

8.  Parallel Receive Beamforming Improves the Performance of Focused Transmit-Based Single-Track Location Shear Wave Elastography.

Authors:  Rifat Ahmed; Marvin M Doyley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-01       Impact factor: 2.725

9.  Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting.

Authors:  Mingyue Yu; Yang Li; Teng Ma; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

10.  A novel adaptive apodization to improve the resolution of phased subarray imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2019-09-20       Impact factor: 1.314

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.