Literature DB >> 18234487

An impedimetric immunosensor based on interdigitated microelectrodes (IDmicroE) for the determination of atrazine residues in food samples.

Javier Ramón-Azcón1, Enrique Valera, Angel Rodríguez, Alejandro Barranco, Begoña Alfaro, Francisco Sanchez-Baeza, M-Pilar Marco.   

Abstract

A novel impedimetric immunosensor for atrazine detection has been developed. The immunosensor is based on an array of interdigitated micro-electrodes (IDmicroE) and immunoreagents specifically developed to detect this pesticide. Immunochemical determination of atrazine is possible without the use of any label. An atrazine-haptenized protein was covalently immobilized on the surface of the interdigitated mu-electrodes area (interdigits space) previously activated with (3-glycidoxypropyl)trimethoxysilane. Before, the gold electrodes were blocked using N-acetylcysteamine to prevent non-specific adsorptions. All biofunctionalization steps were characterized by chemical affinity methods and impedance spectroscopy. Immunosensors measures are made by exposing the sensor to solutions containing a mixture of the analyte and the specific antibody. With this configuration, the immunosensor detects atrazine with a limit of detection of 0.04 microg L(-1) without the use of any label. The potential of the immunosensor to analyze pesticide residues in complex sample matrices, such as red wine, has been evaluated. The results shown that after solid-phase extraction atrazine can be determined in this type of sample with a limit of detection of 0.19 microg L(-1), far below the Maximum Residue Level (MRL) established by EC for residues of this herbicide in wine.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18234487     DOI: 10.1016/j.bios.2007.12.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

2.  Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Biosens Bioelectron       Date:  2010-03-18       Impact factor: 10.618

3.  A label-free electrochemical immunosensor for carbofuran detection based on a sol-gel entrapped antibody.

Authors:  Xia Sun; Shuyuan Du; Xiangyou Wang; Wenping Zhao; Qingqing Li
Journal:  Sensors (Basel)       Date:  2011-10-10       Impact factor: 3.576

4.  Amperometric immunosensor for carbofuran detection based on MWCNTs/GS-PEI-Au and AuNPs-antibody conjugate.

Authors:  Ying Zhu; Yaoyao Cao; Xia Sun; Xiangyou Wang
Journal:  Sensors (Basel)       Date:  2013-04-19       Impact factor: 3.576

5.  Carbon paste electrode modified with cuo-nanoparticles as a probe for square wave voltammetric determination of atrazine.

Authors:  Nadereh Rahbar; Hooshang Parham
Journal:  Jundishapur J Nat Pharm Prod       Date:  2013-07-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.