Literature DB >> 18231742

The early outcomes with titanium radial head implants in the treatment of radial head comminuted fractures.

Jijun Zhao1, Shuhua Yang, Yong Hu.   

Abstract

The study assessed the early functional outcomes with cemented titanium implants of radius in the treatment of comminuted fractures of radial heads. The functional outcomes of arthroplasty with cemented titanium implants of radius in the treatment of radial head fractures (Mason Type III: 6; Mason Type IV: 4) in 10 consecutive patients (mean age, 38 years) were evaluated over a mean time of 23.7 months (18-31 months). The patients were assessed on the basis of physical examination, functional rating (Mayo) and radiographic findings. The parameters evaluated included motion, stability, pain, and grip strength. Five patients were considered to have excellent results, 4 patients had good results and 1 patient had fairly good results. There were no cases of infection, prosthetic failure, heterotopic ossification or dislocation. When medial collateral ligament was injured, radial head became the main stabilizing structure of the elbow. Titanium radial head implant may provide the stability similar to that of native radial head. We believe that titanium radial head implants may be indicated for the Mason Type III and Mason Type IV radial head fractures.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18231742     DOI: 10.1007/s11596-007-0616-x

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  6 in total

1.  A floating prosthesis for radial-head fractures.

Authors:  T Judet; C Garreau de Loubresse; P Piriou; G Charnley
Journal:  J Bone Joint Surg Br       Date:  1996-03

2.  Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow.

Authors:  F Van Glabbeek; R P Van Riet; J A Baumfeld; P G Neale; S W O'Driscoll; B F Morrey; K-N An
Journal:  J Bone Joint Surg Am       Date:  2004-12       Impact factor: 5.284

3.  The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review.

Authors:  I J Harrington; A Sekyi-Otu; T W Barrington; D C Evans; V Tuli
Journal:  J Trauma       Date:  2001-01

4.  Late results in fractures of the radial head treated by excision.

Authors:  Z D Mikíc; S M Vukadinovíc
Journal:  Clin Orthop Relat Res       Date:  1983-12       Impact factor: 4.176

5.  Associated injuries complicating radial head fractures: a demographic study.

Authors:  Roger P van Riet; Bernard F Morrey; Shawn W O'Driscoll; Francis Van Glabbeek
Journal:  Clin Orthop Relat Res       Date:  2005-12       Impact factor: 4.176

6.  Radial head fractures and their effect on the distal radioulnar joint. A rationale for treatment.

Authors:  C W Geel; A K Palmer
Journal:  Clin Orthop Relat Res       Date:  1992-02       Impact factor: 4.176

  6 in total
  3 in total

1.  [Endoprosthetics of acute radial head fractures].

Authors:  K J Burkhart; K Wegmann; C Ries; L P Müller
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

2.  The clinical implications of heterotopic ossification in patients treated with radial head replacement for trauma: A case series and review of the literature.

Authors:  Seth H Bowman; William R Barfield; Harris S Slone; Gerald J Shealy; Zeke J Walton
Journal:  J Orthop       Date:  2016-06-28

Review 3.  Functional outcomes post-radial head arthroplasty: a systematic review of literature.

Authors:  Manraj Nirmal Kaur; Joy C MacDermid; Ruby R Grewal; Paul W Stratford; Linda J Woodhouse
Journal:  Shoulder Elbow       Date:  2014-03-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.