Literature DB >> 18230516

Feasible images and practical stopping rules for iterative algorithms in emission tomography.

J Llacer1, E Veklerov.   

Abstract

The discussion of the causes of image deterioration in the maximum-likelihood estimator (MLE) method of tomographic image reconstruction, initiated with the publication of a stopping rule for that iterative process (E. Veklerov and J. Llacer, 1987) is continued. The concept of a feasible image is introduced, which is a result of a reconstruction that, if it were a radiation field, could have generated the initial projection data by the Poisson process that governs radioactive decay. From the premise that the result of a reconstruction should be feasible, the shape and characteristics of the region of feasibility in projection space are examined. With a new rule, reconstructions from real data can be tested for feasibility. Results of the tests and reconstructed images for the Hoffman brain phantom are shown. A comparative examination of the current methods of dealing with MLE image deterioration is included.

Year:  1989        PMID: 18230516     DOI: 10.1109/42.24867

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

Review 2.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

3.  A non-negative fast multiplicative algorithm in 3D scatter-compensated SPET reconstruction.

Authors:  S H Walrand; L R van Elmbt; S Pauwels
Journal:  Eur J Nucl Med       Date:  1996-11

4.  Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

Authors:  Moulay Ali Nassiri; Jean-François Carrier; Philippe Després
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

5.  Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology.

Authors:  Albert Flotats; Ignasi Carrió; Denis Agostini; Dominique Le Guludec; Claudio Marcassa; Michael Schäfers; Michael Schaffers; G Aernout Somsen; Mustafa Unlu; Hein J Verberne
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

6.  Improved iterative image reconstruction using variable projection binning and abbreviated convolution.

Authors:  P Schmidlin
Journal:  Eur J Nucl Med       Date:  1994-09

7.  Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

Authors:  Bao Yang; Leslie Ying; Jing Tang
Journal:  IEEE Trans Med Imaging       Date:  2018-06       Impact factor: 10.048

Review 8.  Quantitative statistical methods for image quality assessment.

Authors:  Joyita Dutta; Sangtae Ahn; Quanzheng Li
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.