Literature DB >> 18222900

A high resolution PET for animal studies.

M Watanabe1, H Uchida, H Okada, K Shimizu, N Satoh, E Yoshikawa, T Ohmura, T Yamashita, E Tanaka.   

Abstract

In the PET system a block detector, which is a position-sensitive photomultiplier (PMT) tube coupled to four arrays of 1.7-mm-wide BGO crystals, is utilized. Fifteen block detectors are positioned to form a 35-cm-diameter ring, with four BGO arrays coupled to each PMT. This provides four detector rings, giving the system a 7-slice imaging capability. The gantry head tilts up to +/-90 degrees , and is capable of moving up and down by 30 cm. These positioning capabilities allow flexibility and great ease of use in subject positioning. A gantry entrance size of 22 cm in diameter allows studies ranging from rats and mice to primates such as Rhesus and squirrel monkeys. The physical performance of the system has been evaluated.

Entities:  

Year:  1992        PMID: 18222900     DOI: 10.1109/42.192694

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Quantitative fluorine 18 deoxyglucose uptake by myocardial positron emission tomography in rats.

Authors:  Nobuhiro Handa; Yasuhiro Magata; Eiji Tadamura; Takahiro Mukai; Takeshi Nishina; Senri Miwa; Yutaka Sakakibara; Takuya Nomoto; Junji Konishi; Kazunobu Nishimura; Masashi Komeda
Journal:  J Nucl Cardiol       Date:  2002 Nov-Dec       Impact factor: 5.952

2.  Evaluation of the brain uptake properties of [1-11C]labeled hexanoate in anesthetized cats by means of positron emission tomography.

Authors:  Y Sakiyama; K Ishiwata; K Ishii; K Oda; H Toyama; S Ishii; H Nakayama; A Sato; M Senda
Journal:  Ann Nucl Med       Date:  1996-08       Impact factor: 2.668

3.  Effects of binge pattern cocaine administration on dopamine D1 and D2 receptors in the rat brain: an in vivo study using positron emission tomography.

Authors:  H Tsukada; J Kreuter; C E Maggos; E M Unterwald; T Kakiuchi; S Nishiyama; M Futatsubashi; M J Kreek
Journal:  J Neurosci       Date:  1996-12-01       Impact factor: 6.167

4.  NEMA NU 4-2008 comparison of preclinical PET imaging systems.

Authors:  Andrew L Goertzen; Qinan Bao; Mélanie Bergeron; Eric Blankemeyer; Stephan Blinder; Mario Cañadas; Arion F Chatziioannou; Katherine Dinelle; Esmat Elhami; Hans-Sonke Jans; Eduardo Lage; Roger Lecomte; Vesna Sossi; Suleman Surti; Yuan-Chuan Tai; Juan José Vaquero; Esther Vicente; Darin A Williams; Richard Laforest
Journal:  J Nucl Med       Date:  2012-06-14       Impact factor: 10.057

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.