Objective analysis of ultrasound images by use of a computational observer.

H Lopez1, M H Loew, D J Goodenough.   

Abstract

The design, implementation, and testing of a computational observer method for objective evaluation of ultrasound images are presented. The method uses digitized ultrasound B-scan images of a test phantom (the contrast-detail phantom), and is able to calculate the detectability of a target (signal) from its background (background noise). A quantitative detectability index, based on the measured signal-to-noise ratio of the image data, that is measured for both the human and the computational observer on the same scale is generated. It is shown that the computational observer (CO) method may be a more useful, objective way of evaluating ulrasound images and imaging systems than methods that rely solely on human observers. It may also be applicable to other types (i.e. other than ultrasound) of imaging systems which produce noisy images. The relevance of the CO method when compared to human observer two-alternative-forced-choice (2AFC) readings of the same data by showing a high correlation between the CO detectability results and those of human observers for the same set of images. The method is (1) quantitative, (2) reproducible, (3) absolute, (4) takes into account, and can calculate the value of TPF and FPF for each target, for the given system, and (5) speeds up the evaluation of an image or imaging system (compared to using human observers), given the right conditions and equipment.

Entities:  

Year:  1992        PMID: 18222891     DOI: 10.1109/42.192685

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Low-echo sphere phantoms and methods for assessing imaging performance of medical ultrasound scanners.

Authors:  Ernest L Madsen; Chihwa Song; Gary R Frank
Journal:  Ultrasound Med Biol       Date:  2014-04-24       Impact factor: 2.998

2.  Comparison of the low-contrast detectability of two ultrasound systems using a grayscale phantom.

Authors:  Robert Lorentsson; Nasser Hosseini; Jan-Olof Johansson; Wiebke Rosenberg; Benny Stenborg; Lars Gunnar Månsson; Magnus Båth
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

3.  Computational-observer analysis of illumination discrimination.

Authors:  Xiaomao Ding; Ana Radonjic; Nicolas P Cottaris; Haomiao Jiang; Brian A Wandell; David H Brainard
Journal:  J Vis       Date:  2019-07-01       Impact factor: 2.240

4.  Systematic optimization of ultrasound grayscale imaging presets and its application in abdominal scanning.

Authors:  Zaiyang Long; Wei Zhou; Donald J Tradup; Scott F Stekel; Matthew R Callstrom; Nicholas J Hangiandreou
Journal:  J Appl Clin Med Phys       Date:  2020-08-11       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.