Literature DB >> 18218542

Triple energy window scatter correction technique in PET.

L Shao1, R Freifelder, J S Karp.   

Abstract

A practical triple energy window technique (TEW) is proposed, which is based on using the information in two lower energy windows and one single calibration, to estimate the scatter within the photopeak window. The technique is basically a conventional dual-window technique plus a modification factor, which can partially compensate object-distribution dependent scatters. The modification factor is a function of two lower scatter windows of both the calibration phantom and the actual object. In order to evaluate the technique, a Monte Carlo simulation program, which simulates the PENN-PET scanner geometry, was used. Different phantom activity distributions and phantom sizes were tested to simulate brain studies, including uniform and nonuniform distributions. The results indicate that the TEW technique works well for a wide range of activity distributions and object sizes. The comparisons between the TEW and dual window techniques show better quantitative accuracy for the TEW, especially for different phantom sizes. The technique is also applied to experimental data from a PENN-PET scanner to test its practicality.

Year:  1994        PMID: 18218542     DOI: 10.1109/42.363104

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

2.  A method for calibrating three-dimensional positron emission tomography without scatter correction.

Authors:  D L Bailey; T Jones
Journal:  Eur J Nucl Med       Date:  1997-06

Review 3.  Applications of artificial intelligence in nuclear medicine image generation.

Authors:  Zhibiao Cheng; Junhai Wen; Gang Huang; Jianhua Yan
Journal:  Quant Imaging Med Surg       Date:  2021-06

4.  Novel scatter compensation of list-mode PET data using spatial and energy dependent corrections.

Authors:  Bastien Guérin; Georges El Fakhri
Journal:  IEEE Trans Med Imaging       Date:  2010-11-29       Impact factor: 10.048

5.  Data-driven, energy-based method for estimation of scattered events in positron emission tomography.

Authors:  Nikos Efthimiou; Joel S Karp; Suleman Surti
Journal:  Phys Med Biol       Date:  2022-04-21       Impact factor: 4.174

  5 in total