Literature DB >> 18218381

Simulation evaluation of Gibbs prior distributions for use in maximum a posteriori SPECT reconstructions.

D S Lalush1, B W Tsui.   

Abstract

The effects of several of Gibbs prior distributions in terms of noise characteristics, edge sharpness, and overall quantitative accuracy of the final estimates obtained from an iterative maximum a posteriori (MAP) procedure applied to data from a realistic chest phantom are demonstrated. The effects of the adjustable parameters built into the prior distribution on these properties are examined. It is found that these parameter values influence the noise and edge characteristics of the final estimate and can generate reconstructions closer to the actual solution than maximum likelihood (ML). In addition, it is found that the choice of the shape of the prior distribution affects the noise characteristics and edge sharpness in the final estimate.

Entities:  

Year:  1992        PMID: 18218381     DOI: 10.1109/42.141651

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

Review 1.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

2.  A new decision rule for parameter delta in MAP EM (OSL) reconstruction with the Gibbs prior.

Authors:  K Ogawa; K Hiruma
Journal:  Ann Nucl Med       Date:  1996-08       Impact factor: 2.668

3.  Preconditioned Alternating Projection Algorithms for Maximum a Posteriori ECT Reconstruction.

Authors:  Andrzej Krol; Si Li; Lixin Shen; Yuesheng Xu
Journal:  Inverse Probl       Date:  2012-11       Impact factor: 2.407

4.  Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Authors:  Lishui Cheng; Robert F Hobbs; George Sgouros; Eric C Frey
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.

Authors:  Taek-Soo Lee; Takahiro Higuchi; Riikka Lautamäki; Frank M Bengel; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2015-08-24       Impact factor: 3.609

6.  Multi-Tracer Guided PET Image Reconstruction.

Authors:  Sam Ellis; Andrew Mallia; Colm J McGinnity; Gary J R Cook; Andrew J Reader
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-23

7.  Reduction of collimator correction artefacts with bayesian reconstruction in spect.

Authors:  Tuija Kangasmaa; Antti Sohlberg; Jyrki T Kuikka
Journal:  Int J Mol Imaging       Date:  2010-12-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.