Literature DB >> 18217777

Protein-resistant poly(ethylene oxide)-grafted surfaces: chain density-dependent multiple mechanisms of action.

Larry D Unsworth1, Heather Sheardown, John L Brash.   

Abstract

A clear understanding of the mechanisms responsible for the protein-resistant nature of end-tethered poly(ethylene oxide) (PEO) surfaces remains elusive. A barrier to improved understanding is the fact that many of the factors involved (chain length, chain density, hydration, conformation, and distal chemistry) are inherently correlated. We hypothesize that, by comparing systems of variable but precisely known chain density, it should be possible to gain additional insight into the effects of the other factors. To evaluate this hypothesis, chain-end-thiolated PEOs were chemisorbed to gold-coated silicon wafers such that a range of chain densities was obtained. Three different PEOs were investigated: hydroxy-terminated chains of molecular weight 600 (600-OH), methoxy-terminated chains of molecular weight 750 (750-OCH3), and methoxy-terminated chains of molecular weight 2000 (2000-OCH3). In situ null ellipsometry was used to determine PEO chemisorption kinetics, ultimate PEO chain densities, protein adsorption kinetics, and ultimate protein adsorbed quantities. With this approach, it was possible to ascertain the effects of PEO distal chemistry (-OH, -OCH3), chain length, and layer hydration on protein adsorption. The data obtained suggested that properties related to chain density (conformational freedom, hydration) were the main determinants of protein resistance at chain densities up to a critical value of approximately 0.5 chain/nm2; at this value, protein adsorption was a minimum for the methoxy-terminated PEOs. For the hydroxyl-terminated PEO, adsorption leveled off at the critical value. Thus distal chemistry appears to be a major determinant of protein resistance at chain densities greater than the critical value.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18217777     DOI: 10.1021/la702310t

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  30 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

2.  An X-ray and neutron reflectometry study of 'PEG-like' plasma polymer films.

Authors:  Donna J Menzies; Andrew Nelson; Hsin-Hui Shen; Keith M McLean; John S Forsythe; Thomas Gengenbach; Celesta Fong; Benjamin W Muir
Journal:  J R Soc Interface       Date:  2011-09-28       Impact factor: 4.118

3.  Multifunctional Dendrimer-templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection.

Authors:  Hye Jung Han; Rangaramanujam M Kannan; Sunxi Wang; Guangzhao Mao; Juan Pedro Kusanovic; Roberto Romero
Journal:  Adv Funct Mater       Date:  2010-02-08       Impact factor: 18.808

Review 4.  Engineering biomaterials to integrate and heal: the biocompatibility paradigm shifts.

Authors:  James D Bryers; Cecilia M Giachelli; Buddy D Ratner
Journal:  Biotechnol Bioeng       Date:  2012-05-24       Impact factor: 4.530

5.  Anti-inflammatory polymeric coatings for implantable biomaterials and devices.

Authors:  Amanda W Bridges; Andrés J García
Journal:  J Diabetes Sci Technol       Date:  2008-11

6.  Reduced acute inflammatory responses to microgel conformal coatings.

Authors:  Amanda W Bridges; Neetu Singh; Kellie L Burns; Julia E Babensee; L Andrew Lyon; Andrés J García
Journal:  Biomaterials       Date:  2008-09-19       Impact factor: 12.479

7.  Single-molecule resolution of interfacial fibrinogen behavior: effects of oligomer populations and surface chemistry.

Authors:  Mark Kastantin; Blake B Langdon; Erin L Chang; Daniel K Schwartz
Journal:  J Am Chem Soc       Date:  2011-03-10       Impact factor: 15.419

8.  Structural attributes affecting peptide entrapment in PEO brush layers.

Authors:  Marsha C Lampi; Xiangming Wu; Karl F Schilke; Joseph McGuire
Journal:  Colloids Surf B Biointerfaces       Date:  2013-01-26       Impact factor: 5.268

9.  Mode of lysozyme protein adsorption at end-tethered polyethylene oxide brushes on gold surfaces determined by neutron reflectivity.

Authors:  Warren Taylor; Stephen Ebbens; Maximillian W A Skoda; John R P Webster; Richard A L Jones
Journal:  Eur Phys J E Soft Matter       Date:  2015-03-09       Impact factor: 1.890

10.  Challenges and opportunities in the advancement of nanomedicines.

Authors:  Alexander Wei; Jonathan G Mehtala; Anil K Patri
Journal:  J Control Release       Date:  2012-10-12       Impact factor: 9.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.