Literature DB >> 18215801

A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures.

Rui Jiang1, Cong-Feng Luo, Ming-Chun Wang, Tie-Yi Yang, Bing-Fang Zeng.   

Abstract

The present investigation is a prospective study comparing the use of locked plates and classic double plates for the repair of bicondylar tibial plateau fractures. Eighty-four patients with bicondylar tibial plateau fractures were treated with plate fixation by either a locked plate (Less Invasive Stabilization System, LISS) or classic double plates (DP). All patients were followed for a minimum of 24 months. Outcomes were assessed by recording the surgical experience with each approach, post-operative complications and improvements in knee function as measured by the Hospital for Special Surgery (HSS) score. For all patients, no differences in the mechanisms of injury, fracture type, open fracture grade, mean age, gender distribution, associated medical conditions, pre-surgical stay, surgical time, bony union rate or radiographic healing times were observed between the two groups. Also, the HSS score and incidences of infection, seroma, hematoma, deep venous thrombosis, loss of reduction, loss of alignment, hardware failure and overall post-operative complications were all similar in both groups (P>0.05). Wound size and blood loss were significantly less in the LISS group than in the DP group (both P<0.05). A significantly higher incidence of post-operative malalignment of the proximal tibia (P=0.041) and a trend toward significance of a higher incidence of symptomatic hardware irritation (P=0.057) were observed in the LISS group compared to the DP group. In conclusion, LISS provides an alternative treatment for bicondylar tibial plateau fractures, but it may not replace the conventional two-incision double plating technique as the standard of care.

Entities:  

Mesh:

Year:  2008        PMID: 18215801     DOI: 10.1016/j.knee.2007.12.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  30 in total

1.  High energy tibial plateau fractures treated with hybrid external fixation.

Authors:  George C Babis; Dimitrios S Evangelopoulos; Panagiotis Kontovazenitis; Konstantinos Nikolopoulos; Panagiotis N Soucacos
Journal:  J Orthop Surg Res       Date:  2011-07-14       Impact factor: 2.359

2.  Fixation augmentation using calcium-phosphate bone substitute improves outcomes of complex tibial plateau fractures. A matched, cohort study.

Authors:  Matthieu Ollivier; Yassine Bulaïd; Christophe Jacquet; Sebastien Pesenti; Jean-Noel Argenson; Sebastien Parratte
Journal:  Int Orthop       Date:  2018-04-07       Impact factor: 3.075

3.  Patient-related outcomes after proximal tibial fractures.

Authors:  Daniel Wenger; Karolin Petersson; Cecilia Rogmark
Journal:  Int Orthop       Date:  2018-04-07       Impact factor: 3.075

Review 4.  Meta-analysis shows that highly comminuted bicondylar tibial plateau fractures treated by single lateral locking plate give similar outcomes as dual plate fixation.

Authors:  Hengrui Chang; Yanbin Zhu; Zhanle Zheng; Wei Chen; Shue Zhao; Yiwen Zhang; Yingze Zhang
Journal:  Int Orthop       Date:  2016-03-23       Impact factor: 3.075

5.  Reply to comments on Chang et al.: Meta-analysis shows that highly comminuted bicondylar tibial plateau fractures treated by single lateral locking plate give similar outcomes as dual plate fixation.

Authors:  Hengrui Chang; Yanbin Zhu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-04-22       Impact factor: 3.075

6.  Comparison of the pre-shaped anatomical locking plate of 3.5 mm versus 4.5 mm for the treatment of tibial plateau fractures.

Authors:  Matthieu Ehlinger; Benjamin Adamczewski; Michel Rahmé; Philippe Adam; Francois Bonnomet
Journal:  Int Orthop       Date:  2015-03-08       Impact factor: 3.075

7.  Locking and Non-locking Constructs Achieve Similar Radiographic and Clinical Outcomes for Internal Fixation of Intra-articular Distal Humerus Fractures.

Authors:  Marschall Berkes; Grant Garrigues; John Solic; Nathan Van Zeeland; Nader Shourbaji; Kim Brouwer; Jesse Jupiter; David Ruch; William T Obremskey
Journal:  HSS J       Date:  2011-09-15

8.  Minimally invasive and open surgical treatment of proximal tibia fractures using a polyaxial locking plate system: a prospective multi-centre study.

Authors:  Jens A Jöckel; Johannes Erhardt; Miscia Vincenti; Jörg Reissig; Reinhard Hoffmann; Baher Husain; Gert Täger; Axel Partenheimer; Helmut Lill; Florian Gebhard; Götz Röderer
Journal:  Int Orthop       Date:  2013-02-16       Impact factor: 3.075

9.  Management of the Schatzker VI fractures with lateral locked screw plating.

Authors:  Rosario Spagnolo; Fabrizio Pace
Journal:  Musculoskelet Surg       Date:  2011-11-27

10.  Utilization of the less-invasive stabilization system internal fixator for open fractures of the proximal tibia: a multi-center evaluation.

Authors:  James P Stannard; Christopher G Finkemeier; Jackson Lee; Philip J Kregor
Journal:  Indian J Orthop       Date:  2008-10       Impact factor: 1.251

View more