Literature DB >> 18215373

[Influence of helix angle and density on primary stability of immediately loaded dental implants: three-dimensional finite element analysis].

Pan Ma1, Hong-chen Liu, De-hua Li, Sheng Lin, Zhen Shi, Qin-jian Peng.   

Abstract

OBJECTIVE: To analyze effects of different thread helix angles and densities on the primary stability of immediately loaded implants using the three-dimensional finite element model analysis.
METHODS: Five models of three-dimensional finite element (0.8 mm, 1.6 mm, 2.4 mm, double-threaded, and triple-threaded) were created using the commercial codes of Pro/E software, Hypermesh software, and ABAQUS software. In conditions of horizontal and vertical loading, the micro-motion of the finite element models with different thread helix angles and densities were computed with ABAQUS software.
RESULTS: Concerning different thread helix angles, the micro-motion of single-threaded implant was the minimum and that of the triple-threaded was the maximum with vertical and horizontal loading. The micro-motion of doubled-threaded implant was the minimum compared with thread pitch 1.6 mm and the micro-motion of triple-threaded implant was the minimum compared with thread pitch 2.4 mm with vertical and horizontal loading.
CONCLUSIONS: The thread helix angle and density of implants can greatly affect the vertical interfacial micro-motion. With increasing thread pitchs, the resistance of implant to vertical load is weakened; with increasing thread helix angle, the resistance of implant to vertical load is weakened; with increasing thread density, the resistance of implant to the vertical load is weakened.

Mesh:

Substances:

Year:  2007        PMID: 18215373

Source DB:  PubMed          Journal:  Zhonghua Kou Qiang Yi Xue Za Zhi        ISSN: 1002-0098


  3 in total

1.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

2.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

3.  Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs.

Authors:  Yee-Seo Kwon; Hee Namgoong; Jung-Hoon Kim; In Hee Cho; Myung Duk Kim; Tae Gwan Eom; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614